WPC 2000 User Manual
3-48
Initialization, Setup, and Checkout
3.
Check for fault codes on the LED display.
•
If a fault code between F80 and F89 (or between H80 and H89) displays, there is a
problem with the overrun limit switch. Try the remedies suggested for overrun limit
switch faults, starting on page 5-18; then, inch the ram to the top of the stroke and run
the test again, starting with step 2. If the ram still does not make a complete stroke or
does not stop at top dead center, call Wintriss Tech. Support.
•
If the LED display is blank or shows an error other than an overrun limit switch fault,
check and correct the wiring of the palm buttons and light curtains, correcting any
problems; then, run the test again, starting with step 2. If the ram still does not complete
a stroke or stop at top dead center, call Wintriss Tech. Support.
4.
Turn the Stroke Select switch to “INCH,” and bring the ram to top dead center.
5.
Press and then immediately release the Run/Inch palm buttons, observing the behavior of
the ram.
•
If the ram moves when you press the Run/Inch buttons, then stops when you release
them, and the Interrupted Stroke LED flashes, go to the next step.
•
If the ram does not move, or if it moves but does not stop immediately when you release
the Run/Inch buttons, or if the Interrupted Stroke LED does not flash, check the wiring
of the palm buttons and light curtains, correcting any problems, and run the test again,
repeating step 5. If the ram still does not move or moves but does not stop immediately,
or if the ram stops but the Interrupted Stroke LED does not flash, call Wintriss Tech.
Support.
6.
Complete the stroke by pressing and holding the Run/Inch palm buttons.
7.
Go to the next applicable test.
Anti-tiedown Test
INJURY DURING TESTING
• Keep all personnel away from the press during testing.
• Be sure there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
OPERATOR STATION MAY NOT MEET SAFETY REQUIREMENTS
• Ensure that the Operator Station is wired correctly.
• Ensure that on any non-Wintriss Operator Station the Run buttons are placed so that two hands
are required to push both buttons at the same time and no one can press both buttons with one
hand or with one hand and one elbow.
• Ensure that on any non-Wintriss Operator Station the Run buttons have ring guards or other
means in place to prevent unintentional operation.
Failure to comply with these instructions will result in death or serious injury.
DANGER
!
DANGER
!
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......