WPC 2000 User Manual
1128500
Initialization, Setup, and Checkout
3-33
Switch 6 – Selecting Concurrent Time for More Than Two Operator Stations
Option switch 6 on S102 allows you to select a 5-second concurrent time for WPC 2000
configurations with more than two Operator Stations installed, as shown in Table 3-15.
Concurrent time is the 5-second interval within which each pair of palm switches on all
connected Operator Stations must be activated in order to start the press. If the concurrent
time is exceeded, the press will not start.
When switch 6 is set to OFF, its default position, and two Operator Stations are connected to
WPC 2000, the palm switches on each Operator Station must be pressed within a 1/2-second
window (called the “palm” or “synchronous” time) and both pairs of palm switches must be
pressed within a 5-second concurrent time window in order to stroke the press.
When switch 6 is set to ON and more than two Operator Stations are connected to WPC 2000,
palm switches on all connected Operator Stations must be pressed within a 5-second
concurrent time window to start the press. All Op. Stations connected to the “B” inputs must
contain a Two-hand Control module to provide the required 1/2-second palm (or
synchronous) time.
Setting Programmable Cams
If you have ordered the optional four-channel programmable cam output, you can set cam
“on” and “off” angles via the WPC 2000 display. Before making settings, verify that the cam
outputs have been installed correctly (see page 2-35).
You should only change this switch from its default setting if you have installed more than two
Operator Stations on your WPC 2000. Contact Wintriss Tech. Support for further information.
Do not attempt to install more than two Operator Stations until you have contacted Wintriss Tech.
Support. All Operator Stations in a mutli-Op.-Station configuration except the Op. Station wired to
the “A” inputs must contain a Two-hand Control module. Do not order standard Wintriss “Multiple
Operator Stations.”
Table 3-15. Switch 6 Settings (S102): Selecting Concurrent Time for Multiple Op. Stations
Setting
Concurrent Time for Multiple Op. Stations
OFF
Normal Operation (Default). Establishes a 1/2-second palm (or synchronous)
time and a 5-second concurrent time for two Operator Stations.
ON
Establishes a concurrent time of 5 seconds when more than two Operator
Stations are connected to WPC 2000. Also keeps a 1/2-second palm (or
synchronous) time for the Op. Station connected to the “A” inputs. Each
Operator Station connected to the “B” inputs must contain a Two-hand
Control module to provide the required 1/2-second palm (or synchronous)
time.
NOTICE
NOTICE
Summary of Contents for wpc 2000
Page 91: ...1128500 WPC 2000 User Manual 2 64 Installation ...
Page 191: ...1128500 WPC 2000 User Manual 5 22 Troubleshooting ...
Page 209: ...1128500 WPC 2000 User Manual A 18 Extracts from OSHA and ANSI ...
Page 225: ...1128500 WPC 2000 User Manual G 6 Glossary ...
Page 231: ......
Page 232: ......
Page 233: ......
Page 234: ......
Page 235: ......
Page 236: ......
Page 237: ......
Page 238: ......
Page 239: ......
Page 240: ......
Page 241: ......
Page 242: ......
Page 243: ......
Page 244: ......
Page 245: ......
Page 246: ......
Page 247: ......
Page 248: ......
Page 249: ......
Page 250: ......