Addendum
October 2021
1146200
SMI 2 User Guide
Rev. C
Page 30
Figure 25 - Hold State Settings
Release Hold State
–
There are 3 options. One, release hold state manually by selecting the hold state
button. Two, release hold state when X number of cycles are produced. Three, release hold state after
X number of seconds. Note: the operator can un-hold the state at any time by selecting the hold state
button.
‘
Manual
’
–
if
‘
Release Hold State
’
is set to
‘
Seconds
’
or
‘
Cycles
’
, then you can enter in the number of
cycles or seconds by selecting this button.
‘
Count in Hold State
’
–
when enabled the SMI 2 will increment its good parts count when the cycle
input is actuated regardless of whether the state is being held or not.
‘
Hold state On New Job
’
–
when enabled the state will be held when loading a new job.
‘
Hold State ON Downtime
’
–
when enabled the state will be held when any downtime reason is
selected.
‘
Hide Hold State Button
’
–
when enabled the hold state button is hidden from view.