SMI 2 User Guide
Rev. C
Page 3
Installation
Category
II
Dimensions
Enclosure: 8.00 x 10.08 x 4.00 in. (101.6 x 203.2 x 256.0 mm) NEMA 12, IP 66
Panel mount: 9.2 x 7.7 x 4.25 in. (234 x 196 x 108 mm)
Electrical
(System Power)
Input: 100-240 Vac, 40 W, 50-60 Hz
or
24 Vdc +/- 15%, 30 W
When installed, this equipment shall have, in close proximity and easily
accessible, a switch or circuit breaker marked as the disconnect switch.
Operating
Environment
Indoor use only
Temperature: 32
o
to
122
o
F (0
o
to
50
o
C)
Relative Humidity: Indoor factory conditions
Altitude: 6562 ft (2000 m)
Parts Counter
Total preset for maximum count. Set to 9 digits.
Batch Preset for maximum count. Set to 7 digits.
Inputs
All SMI 2 inputs (sink or source): 9mA ± 2 mA @ 24 Vdc
TB2 Inputs 1-4 (Factory Wired for PNP)
1. Cycle Count
2. Run/Idle
3. Scrap
4. Setup
TB4 Automatic Downtime Inputs 1-4 (Factory Wired for PNP)
1. Downtime Reason 32
2. Downtime Reason 31
3. Downtime Reason 30
4. Downtime Reason 29
Outputs
1 stop circuit (dry contacts): Contact rating 4 A, max, @240 Vac or 30 Vdc
Scanner
(optional)
USB barcode scanner capable of adding a carriage return as a suffix
Wireless
Connection
(optional)
Factory installed
IEEE 802.11 b/g/n