1107200
Shadow VI User Manual
page 46
Chapter 2
Installation and Checkout
The instructions below describe how to wire the Shadow transmitter and receiver to the
control.
Terminating Shields of the Head Cables, next section
Connecting the Head Cables to the Control, page 47
If You Have a Second Set of Shadow Optic Heads, page 49
Terminating Shields of the Head Cables
The shields of the head cables must be terminated close to their entry into the control box.
Follow the instructions in this document for terminating these cable shields.
Follow the steps below to terminate the shields of the cables that connect to your light curtain
heads. Refer to the figure above, the tables on the next page and the figure at the end of this
document.
1. Strip the cable jackets back as far as the end of the conduit fittings.
2. Cut the drain wires to a length that they can reach and be inserted into the set screw
terminal.
3. Loosen the set screw in the set screw terminal. Twist together the ends of the drain wires
and insert in the hole in the set screw terminal under the end of the set screw.
4. Tighten the set screw and check that all drain wires are firmly connected.
5. Connect the rest of the wires in the cables to the terminal blocks as instructed in the next
section.
Set screw terminal
Drain wires
Figure 2-15. Terminating Drain Wires to Set Screw Terminal
Showing Connection for Two Pairs of Heads
Summary of Contents for Shadow VI
Page 142: ...1107200 Shadow VI User Manual page 130 Appendix C Installation of Shadow VI WPC Control Board ...
Page 144: ...1107200 Shadow VI User Manual page 132 Appendix D Replacement Parts ...
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......