Shadow 8 User Manual
1139300
Installation and Checkout
2-53
Machine Run/Stop LED Not Illuminated Green
If the Machine Run/Stop LED on the Main Receiver is not illuminated green and there is no
object in the light field, dirt on one or both lens windows may be blocking a light beam. Try
cleaning the lens windows (see page 4-7 for instructions).
If, after the lens windows have been cleaned, the Machine Run/Stop LED is still not
illuminated green, the next step is to bring the optic heads to within 12 in. of each other (but
no closer). Unbolt either the receiver or transmitter (whichever is more convenient), take the
unbolted unit off its mounting, and hold it directly in front of the other head. You may need to
disconnect and reconnect wiring so the heads will reach.
Make sure the lenses are pointed directly at one another and the Shadow 8 heads are mounted
in the same horizontal and vertical plane.
If the Machine Run/Stop LED is illuminated green after you have brought the heads close
together, there is a problem with your installation. Reread the instructions starting on
page 2-15 to be sure you understand how Shadow 8 heads should be mounted. When you
adjust your brackets so they are in the same horizontal and vertical plane, the Shadow 8
transmitter and receiver should align.
If the Machine Run/Stop LED is not illuminated green after adjusting the mounting brackets,
your Shadow 8s probably have an internal problem. Call Wintriss Tech. Support for
assistance.
Machine Run/Stop LED Is Green But Machine Won’t Start
In a multi-segment system, if the Machine Run/Stop LED on the Main Receiver is red, check for
illuminated IBIs on Extension receivers. Alternately illuminated IBIs indicate that the minimum
number of consecutive beams for that pair of heads are not aligned or are interrupted by a fixed
blanking window. Single illuminated IBIs indicate misaligned LED/phototransistor pairs.
Power down the control before connecting or disconnecting the wires to the heads.
GUARD AGAINST ELECTRIC SHOCK HAZARD
• Ensure that the power source is off before checking or replacing fuses.
• Turn off and disconnect power from the Shadow 8 safety light curtain and from the machinery it
is connected to, including the machine control and motor, before making any wiring
connections.
• Ensure that all procedures are performed by qualified personnel.
Failure to comply with these instructions could result in death or serious injury.
NOTICE
NOTICE
WARNING
!
Summary of Contents for Shadow 8
Page 95: ...1139300 Shadow 8 User Manual 3 10 Operation ...
Page 107: ...1139300 Shadow 8 User Manual 4 12 Troubleshooting ...
Page 111: ...1139300 Shadow 8 User Manual B 2 Checkout Procedure Log ...
Page 113: ...1139300 Shadow 8 User Manual C 2 Test Procedure Log ...
Page 135: ...1139300 Shadow 8 User Manual D 22 Extracts from OSHA and ANSI ...
Page 136: ...Shadow 8 User Manual 1139300 Extracts from OSHA and ANSI D 23 ...
Page 137: ...1139300 Shadow 8 User Manual D 24 Extracts from OSHA and ANSI ...
Page 143: ...1139300 Shadow 8 User Manual I 4 Index ...
Page 146: ......
Page 147: ......
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 159: ......