Version
0.2
31
October
2011
w
ww.switchdiy.com
class:
0x85
COMMAND_CLASS_ASSOCIATION
The
Association
Command
Class
is
used
to
associate
other
devices
with
the
iPlugDim.
Th
e
de
v
ice
s
that
are
associated
can
be
controlled
on
application
level.
Every
time
the
push
button
is
pressed
a
switch
binary
report
is
sent
to
the
associated
node
The
iPlugDim
can
be
asso
c
iate
d
int
o
a
grou
p
ing.
If
so,
the
iPlugDim
can
be
contro
l
le
d
by
anoth
e
r
Z
‐
Z-
Wave
device
(does
not
have
to
be
a
controller).
Number
of
groupings:
1
Maximum
supported
nodes
per
group:
1
Because
only
one
group
is
supported
grouping
identifier
is
ignored
in
all
cases.
class:
0x73
COMMAND_CLASS_POWERLEVEL
The
Powerlevel
Command
Class
defines
the
RF
transmitting
power.
This
command
is
used
to
test
the
connectivity
of
a
network.
The
Command
makes
it
possible
for
supporting
controllers
to
SET/GET
the
RF
transmitting
power
level
of
a
node
and
test
specific
links
between
nodes.
class:
0x75
COMMAND_CLASS_PROTECTION
The
Protection
Command
Class
is
used
to
protect
the
device
being
controlled
unintentional
or
unwanted
by
e.g.
a
child.
When
this
is
applied
the
push
button
will
not
work.
This
can
be
set
using
the
PROTECTION_SET
command.
The
following
three
protection
states
can
be
used:
0x00:
Unprotected
–
The
device
is
not
protected
and
can
be
operated
normally
with
the
push
button.