background image

    Installation safety - must be followed

1. Choise of placement:

• The  ceiling  structure  must  be  able  to  support  at  least  50kg/m²  moving
weight.
• Choose a place where there is no risk for people or objects to contact

with rotating blades.

• The fan must not be installed in a damp room.
• The fan must not be installed near flammable or explosive substances or
gas.
• Follow the requirements of automatic fire alarm systems.
•  Follow  the  requirements  of  infrared  heaters  regarding  the  gas  exhaust
system.

2. To prevent contact with running blades, the fan must be mounted with a

minimum distance of 2,50 m between blades and floor.

3. For the installation of the ceiling j-hook use only fastening parts authorized

for  this  kind  of  ceiling. The  choise  of  the  fastening  parts  and  the  correct
installation of the j-hook is on the responsibility of the installation expert. 

Check all connections for perfect tight before first-time operation.

4. Be sure, that nobody can arrive the danger zone during the operation of

the fans.  Follow the local accident prevention. 

5. The  electric  installation  and  the  repairs  must  be  done  by  a  professional

expert in accordance with all applicable codes and standards.

6.

URGENT:

Before  hanging  the  fan  and  connecting  the  wiring  make  sure

power is off at the main service panel. Tag it to prevent unexpected power
on.

7. Verify that power supply is compatible with rating label markings.

8. The  fan  must  be  protected  by  a  certificated  switch,  with  double  terminal

and contact opening not lower than 3 mm.

9. The wiring must be in accordance to the official norms. The fan must be

connected  to  “earth”:  Make  sure  that  the  green/yellow  wire  of  the  fan  is
tight connected with the green/yellow wire of the power supply.

10. Pay attention to the wires during the installation, in order to prevent any

damage.

11. While installation check all nuts, bolts and cotter pins if they are perfectly

tight, especially inside the two canopies.

- 1 -

Summary of Contents for 03.210

Page 1: ...0335 2 80 2003 A1 A2 EN 61233 2008 Additional examination GPSG IMPORTANT Do not use this fan for other applications without our agree ment Read and follow these instructions carefully to prevent per sonal injury and property damage Keep always this instruc tion booklet 03 210 Manual 03210 Eng R 15 2013 10 Copyright All Rights Reserved Industrial ceiling fan 03 210 03 215 ...

Page 2: ...ontents of the package 2 Mount of the ceiling j hook 2 Mount of the blades 3 Hang the fan and connect wiring 3 Mount of the safety wire 4 Fix the upper canopy 4 Troubleshooting 5 Maintenance 6 Disposal and environmental protection 6 Specifications 6 Industrial ceiling fan 03 210 03 215 ...

Page 3: ...onnections for perfect tight before first time operation 4 Be sure that nobody can arrive the danger zone during the operation of the fans Follow the local accident prevention 5 The electric installation and the repairs must be done by a professional expert in accordance with all applicable codes and standards 6 URGENT Before hanging the fan and connecting the wiring make sure power is off at the ...

Page 4: ...nd repaired by a professional 5 In case of taking out of operation of the product you have to make it unus able For example by removing the power cord Contents of the package 1 motor assembled with downrod rubber grommet and canopies 3 baldes 1 ceiling j hook with safety pin 2 jam screws to fix the upper canopy Mount of the ceiling j hook Mount the ceiling j hook with fastening parts authorized fo...

Page 5: ...hook Make sure not to wedge wires between rubber grommet and ceiling j hook URGENT Place the safety pin in the hole at the end of the ceiling j hook The fan must not used without the original j hook safety pin If the pin is lost order a new one Connect the three wires from supply circuit to the fan terminal as follows the green yellow wire with the grounding the blue wire with the neutral the brow...

Page 6: ...rt at least 40 kg moving weight and hold the safety wire safe Picture example screw eye and carabiner not included Fix the upper canopy Raise the upper canopy to the ceiling Make sure there is 1cm distance bet ween the ceiling and the top of the upper canopy Now fix the upper canopy horizontally with the two jam screws do not over tighten 4 wall plugs example not included ceiling j hook screws exa...

Page 7: ...anopy cotter pin and wires under the lower canopy These parts should not be allowed to touch the motor A slight humming sound if used at an infinitely speed control especially on lower speed is normal for all ceiling fans Use our original speed control not oversized to avoid or minimize this sound Fan wobbles fan is out of balance IMPORTANT For the reason of safety and the risk of material damage ...

Page 8: ...oose Therefore all connections must be checked two times per year for perfect tight Especially the blade screws all nuts bolts and cotter pins inside the two canopies the pin and strength of the ceiling j hook and the safety wire In case of intensive use the checks should be more frequent 4 In case of need use a damp cloth for cleaning Do not use liquid cleaners or aero sol cleaners Never dip the ...