5.5.5
Flow limiting valve
For each cylinder there is one flow limiting valve installed on the fuel rail.
The position of the piston (003,
) gives the quantity of fuel for the injection. When the
injection valves open, the piston (003) moves to the right until the injection stops. When the
injection valves are closed, the piston (003) moves back to the start position.
If the injection time is too long (eg if an injection valve is stuck open), the piston (003) closes the
supply.
If an injection valve is damaged, the flow limiting valve sets the maximum limit of fuel that can be
injected into the cylinder.
Fig 5-32
Flow limiting valve (generic)
Legend
001
Fuel outlet
003
Piston
002
Fuel inlet
X52
AA00-5565-00AAA-043A-A
Operation Manual
Flow limiting valve
Winterthur Gas & Diesel Ltd.
- 170 -
Issue 002 2018-11