background image

LM6 Installation, Operation Manual

Tel: 1-800-WINTERS / www.winters.com

WINTERS INSTRUMENTS

4

Limitation of liability

By non-observance of the operating manual, inappropriate use, modification or damage, no liability is assumed and

warranty claims will be excluded.

Intended use

-

The probes have been developed for continuous level measurement. It is the operator's respon-sibility to check

and verify the suitability of the de-vice for the intended application. If any doubts remain, please contact our 

sales department in order to ensure proper usage. Winters Instruments is not liable for any incorrect selections 

and their effects!

-

Permissible media are gases or liquids, specified in the data sheet. In addition it has to be ensured, that this 

medium is compatible with the media wetted parts. 

-

The technical data listed in the current data sheet are engaging and must be complied with. If the data sheet is 

not available, please order or download it from our homepage. (http://www.winters.com)

Y

WARNING!

Danger through improper usage! 

Package contents

Please verify that all listed parts are undamaged included in the delivery and check for consistency specified in your

order:

-

probe

-

mounting instructions

-

with option SIL2 version: 

Functional Safety Manual, Functional Safety Data Sheet?, SIL Declaration of Conformity

Product identification

The device can be identified by its manufacturing label. It provides the most important data. By the ordering code

the product can be clearly identified.

!

The manufacturing label must not be removed 

from the device!

Mechanical installation

Mounting and safety instructions

Y

WARNING! 

Install the device only when depressurized and currentless!

Y

WARNING!

This device may only be installed by qualified technical personnel who has read and understood 

the operating manual!

!

Handle this high-sensitive electronic precision measuring device with care, both in packed and unpacked 

condition!

!

There are no modifications/changes to be made on the device. 

!

Do not throw the package/device!

!

To avoid damaging the diaphragm, remove packaging and protective cap directly before starting assembly. The

delivered protective cap has to be stored!

Product Code: LM6010
Range: 0...10 PSI
Input: 14...28 VDC
+ Vs: 1 - Vs: 2
Output: 4...20 mA/2-wire

SN 8888888 01.2009
  

:Case

figure 1

Summary of Contents for LM6

Page 1: ...www winters com WINTERS INSTRUMENTS MANUFACTURER OF INDUSTRIAL INSTRUMENTATION LM6 SUBMERSIBLE TRANSMITTER INSTALLATION AND OPERATING MANUAL ...

Page 2: ...s Medium 14 F to 158 F 10 C to 70 C Ex protection Zone 0 14 F to 140 F 10 C to 60 C Zone 1 or higher 14 F to 158 F 10 C to 70 C Storage 13 F to 158 F 25 C to 70 C Reserve Polarity Protection No damage No function Electromagnetic Compatibility Emission and immunity according to EN 61326 Ex protection Option Zone 01 II 1 G Ex ia IIC T4 Zone 20 II 1 D Ex tD A20 IP65 T185 F 85 C Safety technical max v...

Page 3: ...ngerous situation which may result in death or serious injuries Y WARNING potentially dangerous situation which may result in death or serious injuries Y CAUTION potentially dangerous situation which may result in minor injuries CAUTION potentially dangerous situation which may result in physical damage NOTE tips and information to ensure a failure free operation Target group Y WARNING To avoid op...

Page 4: ...ontents Please verify that all listed parts are undamaged included in the delivery and check for consistency specified in your order probe mounting instructions with option SIL2 version Functional Safety Manual Functional Safety Data Sheet SIL Declaration of Conformity Product identification The device can be identified by its manufacturing label It provides the most important data By the ordering...

Page 5: ...the device shall be used in high viscosity media such as sludge a removal of the cap before start up is necessary Thus the sensor becomes flush and the medium will attain quickly to the diaphragm If it is necessary for your application to remove the protection cap this has to be done with utmost care To prevent a damage of the diaphragm please follow these instructions Removal by hand Hold the pro...

Page 6: ...onal resistance of the connecting cable could cause problems this cable has to be checked with the following calculation with RL resistance of connecting cable in ohm p specific resistance in ohm mm m l cable length in m A cross section of conductor in mm with Vtot total voltage drop Rload load resistance to be taken out of the current data sheet the following condition must be fulfilled with VS p...

Page 7: ...ce has to be used within the technical specifications only compare the data in the data sheet Placing out of service Y WARNING When dismantling the device it must always be done in the depressurized and currentless condition Check also if the medium has to be drained off before dismantling Y WARNING Depending on the medium it may cause danger for the user Comply therefore with adequate precautions...

Page 8: ...o the European Directives 2002 96 EG and 2003 108 EG on waste electrical and electronic equipment Waste of electrical and electronic equipment may not be disposed by domestic refuse Y WARNING Depending on the measuring medium deposit on the device may cause danger for the user and the environment Comply with adequate precautions for purification and dispose of it properly Warranty conditions The w...

Page 9: ...WINTERS INSTRUMENTS Tel 1 800 WINTERS www winters com 9 ...

Page 10: ...INTERS Fax 403 723 6647 calgary winters com USA Houston Winters Instruments 5400 W Sam Houston Pkwy N Houston Texas 77041 Tel 281 880 8607 1 800 WINTERS Fax 281 880 8614 usasales winters com Asia Shanghai Winters Instruments Room 203 Building 8 No 471 Guiping Road Shanghai 200233 China Tel 86 21 6104 2610 Fax 86 21 6104 2615 asiasales winters com www wintersasia com Latin America Buenos Aires Wint...

Reviews: