4
|
89014665; 2022-04
|
Assembly instructions
5
Establish the electrical connection of the dosing device
DANGER
Electric shock from live components
A fatal electric shock can occur during installation and maintenance work and when carrying out repairs.
Ø
Isolate and lockout the mains supply to the warewasher.
Ø
Check that there is no voltage present.
Note: Maximum current drain at the transfer strip: 0.5 A. Connect only external dosing devices with their own fuse protection.
Include the dosing device in the protective circuit (PE) of the warewasher.
Ø
Disconnect the warewasher from the electrical mains supply and secure against unintended activation.
Ø
Determine the connection and configuration according to the dosing device type (
Ø
Connect external dosing device to transfer strip.
Ø
Configure the transfer strip (
).
5
4
3
2
1
Item
Name
Note
1
L1
Continuous voltage / phase 1
2
N
Neutral / phase 2
3
RINSE
For rinse aid dosing device
4
WASH
For detergent dosing device (type-dependent)
5
FILL
For detergent dosing device (type-dependent)
Depending on the configuration of the transfer strip, voltage is present at the RINSE and FILL terminals.
Terminal
Voltage present
Condition
Restriction
FILL
While machine fills
– Hood closed
– Minimum water level
in the tank
Parallel to solenoid valve
– While machine fills
– During the rinse
– Hood closed
– Not during the self-cleaning programme
WASH
Parallel to wash pump
– Hood closed
– Not during the self-cleaning programme
– Not while the machine is being filled
– Not during the descaling and basic clean-
ing programme
RINSE
Parallel to rinse pump
– Hood closed
– Not during the self-cleaning programme
– Not while the machine is being filled
– Not during the descaling and basic clean-
ing programme
Parallel to solenoid valve
– While machine fills
– During the rinse
– Hood closed
– Not during the self-cleaning programme