background image

Maintenance and care 

 

11 

 

Maintenance and care 

 

Warning

 

Do not spray the machine or direct vicinity (walls and floor) with a water hose, steam jet or high-
pressure cleaner. 
When cleaning the floor, take care to avoid flooding the substructure of the machine, in order to 
prevent the uncontrolled entry of water. 

8.1  Daily 

An evacuation program is helpful on cleaning the machine. It can be interrupted at any time, for example to 
also clean the machine interior manually (7.1.4). If it is not interrupted, it will run automatically and terminate 
by switching off the machine. 

8.1.1  Starting the drainage programme 

 

  Let the last rack be transported out of the 

machine. 

  Press button 3 to stop rack conveyor 

transport. 

  Button 3 lights up green. 

  Button 2 lights up yellow. 

 

 

  Press button 2 for about 2 seconds and then release it. 

  Button 3 will light up blue. 

  Buttons 2 and 6 blink. 

  The circulating pump circulates the tank water for about two minutes. 

  The interior of the machine is rinsed out with fresh water. 

  About one minute after button 2 has been pressed, the tank water is pumped out and the circulating 

pump continues circulating the tank water. 

  As soon as the tank water has been pumped out to a certain extent, the circulating pump switches 

off.  

  When the rest of the water in the tank has been pumped out, the machine switches off. The buttons 

are not lit up anymore. 

8.1.2  Interrupting the drainage program 

You can interrupt the evacuation program if you want to clean the machine interior manually.

 

  Press button 3, or open the machine door. 

  Button 3 turns green 

  Buttons 2 and 6 continue to flash 

  Clean the machine interior, as described in Chapter 7.1.4. 

8.1.3  Continuing the drainage program 

Water that entered the machine during manual cleaning can now be pumped out:

 

  Press button 2 for about 2 seconds and then release it. Press button 2 again to cancel the operation. 

  Button 2 will flash more rapidly 

  The drain pump will empty the tank 

  The machine will switch itself off when the tank is empty. The buttons are no longer illuminated. 

If the water is not pumped out completely:

 

  Switch off the drain pump (press button 2) 

  The drain is vented (air bubbles rise up) 

  Switch the drain pump on again when there are no more air bubbles rising. 

 

INFO: 

If you do not interrupt the evacuation program, it will run automatically and terminate by switching off 

the machine.

 

  The tank is pumped empty. 

  The tape transport is switched off. 

  The machine switches itself off and the button lights are extinguished. 

 

Summary of Contents for STR series

Page 1: ...Rack conveyor dishwashing machine STR Operating instructions...

Page 2: ......

Page 3: ...equipment 9 7 4 Displaying the temperatures on the control panel 9 7 5 The table limit switch 9 7 6 Routine checks 10 7 7 Switching off the machine 10 8 Maintenance and care 11 8 1 Daily 11 8 1 1 Sta...

Page 4: ...ible defects or damage of the product if the precautionary measures described are not followed Carefully read through the safety notes and operating instructions in this manual before working with thi...

Page 5: ...or sit on the opened hinged door Train the operating personnel as regards handling the machine and inform them about the safety notes Repeat the training sessions at regular intervals to prevent acci...

Page 6: ...tch off the on site mains disconnector main switch Only then is the machine without power Contact your installer or electrician if the on site water or electricity supply is the cause of the malfuncti...

Page 7: ...he machine Have the machine installed by your Winterhalter service technician or dealer Comply with the information in chapter 9 if the installation location is not free of frost Have the machine conn...

Page 8: ...eaker RCCB installed in the building by pressing the test button Open the machine door and check that all filters strainers inline filters for circulating pump and drain pump barrier curtains and wash...

Page 9: ...The machine is supplied from the factory programmed so that it can be started as soon as the rated levels in the tank and the boiler are reached Alternatively the machine can be programmed so that it...

Page 10: ...Rinsing is activated via a second rack switch Leave the washing racks on the outfeed table until the dishes dry if possible For continuous washing however you should remove the washing racks from the...

Page 11: ...rature will take place appears on display A for about five seconds Afterwards the current actual temperature is displayed if continuous display of the temperatures was activated 7 4 7 4 Displaying the...

Page 12: ...s Do not mix different detergent products together Check whether there is detergent or rinse aid in the storage tanks Top them up in time or replace the storage tanks so that the cleaning result will...

Page 13: ...soon as the tank water has been pumped out to a certain extent the circulating pump switches off When the rest of the water in the tank has been pumped out the machine switches off The buttons are not...

Page 14: ...emove it in the direction of the front side Wash out the wash arms if the jets are blocked Remove and clean the strainer Remove the filter A from the tank floor drain If the interior of the machine is...

Page 15: ...ou can descale parts of the interior of the machine yourself by following the instructions below Drain the machine 8 1 1 Interrupt the dosing of detergents e g pull out the suction tube or switch off...

Page 16: ...achine as described in point 8 1 Leave the machine door open Close the water stopcock in the building Switch off the mains disconnector in the building If the machine is installed in a room that is no...

Page 17: ...ter stopcock is opened Switch on the machine again If the fault message appears again do the following Disconnect the machine from the mains and close the water stopcock Tell the Winterhalter service...

Page 18: ...d When the error occurs five times appears When you switch off the machine Err 21 is displayed Close the water stopcock so no more water flows into the machine Tell the Winterhalter service technician...

Page 19: ...nks breaks etc Replace storage tanks Check the dosing equipment Dishes not sorted correctly Do not stack dishes on top of one another Wash arm jets blocked Remove wash arms and clean jets Transport sp...

Page 20: ...achines heated with steam Permitted steam pressure 30 400 kPa 0 3 4 0 bar Permitted steam temperature 107 1 C 151 8 C 11 2 Emissions Noise The emission sound pressure level at a work station LpAeq acc...

Page 21: ...he dummy plug see arrow and install the conductivity electrode supplied with the dosing equipment The bolt for earthing is located directly under the dummy plug Make a new hole if the hole diameter do...

Page 22: ...in the corresponding equipment documents Terminal strip X3 for the electrical connection of the dosing equipment is located in the plinth on the front right hand leg Refer to the machine circuit diag...

Page 23: ......

Page 24: ...me Winterhalterstra e 2 12 88074 Meckenbeuren Deutschland Telefon 49 0 75 42 4 02 0 www winterhalter de info winterhalter de Winterhalter Gastronom GmbH Commercial Dishwashing Systems Winterhalterstra...

Reviews: