background image

89008157  

17 

10.2  Malfunctions calling for the Winterhalter customer service 

 

 
 

red flashing light:

 the temperature in the boiler or the tank is higher than 95° C.  

 
 
 

 
 

Warning, hot surface!

 Switch off machine immediately. The fault symbol will appear (3) 

and the fault code Err 2 or Err 3. Switch off the main switch. 
Notify the Winterhalter customer service immediately. 
 

 
 
If internal faults should combine to make the machine dysfunctional so that it may no longer be run, the ma-
chine will switch off automatically and display a fault code. 
 

Display  

Possible cause 

Remedy 

Machine switches 
off and displays 

Err 

  1 

Fault inside machine 

Notify Winterhalter customer service 

Machine switches 
off and displays 

Err 

  6 

Fault inside machine or  
water drain is clogged 

Notify Winterhalter customer service or remove 
cause of clogging. 

Machine switches 
off and displays 

Err 

19 

Magnetic valve not closing 

Close the water shut-off valve and notify  
Winterhalter customer service.  
 

Machine is 
switched off and 
displays 

Err 

21 

Magnetic valve not closing 

Close the water shut-off valve and notify  
Winterhalter customer service.  
 

Machine switches 
off and displays 
nothing at all 

Fault inside machine 

Notify Winterhalter customer service 

11 Emissions 

Noise 

The workplace-related emissions LpAeq

 

as defined in DIN EN ISO 11202 amount to <60dB(A) 

Water vapor 

Water vapor escapes from the machine while it is running or when the door is opened. Any wooden furniture 
nearby must be shielded to keep it from swelling. 
 

Summary of Contents for GS 310

Page 1: ...triebsanleitung Operating instructions Manuel d utilisation GS 310 Winterhalter Gastronom GmbH Tettnanger Stra e 72 D 88074 Meckenbeuren Telefon 07542 402 0 Telefax 07542 402 199 www winterhalter de i...

Page 2: ......

Page 3: ...y Alterations of the design or intended purpose of the GS 310 cutlery rinsing machine undertaken without the written permission of Winterhalter Gastronom GmbH shall cause the warranty and product liab...

Page 4: ...Do not expose the machine to freezing temperatures Freezing can damage running water systems damaged Sanitary installations Please observe carefully the information in the attached connection diagram...

Page 5: ...een contacts It must be installed near the machine and be easily accessible Connect the machine to your potential equalization system The screw for this connection is located in the machine s base If...

Page 6: ...horough clean ing in an immersion bath for instance Only then can the cutlery dry without spots after being rinsed in the machine Preparing the immersion bath Attention Cleaning agents for commercial...

Page 7: ...5 Control lamp indicating that external water treatment is exhausted only on VE 15 and VE 20 6 Program key for Program 1 7 Temperature indicator for boiler while machine is heating up and when Program...

Page 8: ...s to be washed in a dishwasher beforehand and is only rinsed in the GS 310 Do not open the door while the program is running Hot water could splash out of the ma chine Do not sit or stand on the open...

Page 9: ...stem check Open the door Check whether the filter cassette and flat filter have been inserted properly Check that there are no bits of paper or the like in the interior Close the door Switch on the ma...

Page 10: ...oducts developed by Winterhalter Gastronom These are espe cially designed for Winterhalter Gastronom dishwashers Flip down the bottom panel toward you The reserve container is marked Klarsp ler Rinse...

Page 11: ...will light up blue while the program is run ning The program key 6 turns green as soon as the program is finished Open the door and take the rack out of the machine Shake the rack with the cutlery ba...

Page 12: ...Key 6 Now the temperatures will be indicated as well Press the key 10 to preselect Program 2 Press the program key 6 to start Program 2 To start additional rinsing programs with Program 2 all you now...

Page 13: ...ill switch off automatically The operating panel will no longer be lit Take out the filter cassette and clean it under running water Put the filter cassette back in Open the door slightly There is a c...

Page 14: ...teel Clean the outside of the machine with stainless steel polish We recommend Winterhal ter Gastronom stainless steel cleaner and Winterhalter stainless steel polish If the flat filter is particularl...

Page 15: ...you cannot remedy the fault please get in touch with the responsible Winterhalter customer service Do not open any panels or parts of the machine if you need a tool to do so You may get an electric sh...

Page 16: ...or codes are displayed check whether the water shut off valve is opened Then switch on the machine again If the fault message appears again note the fault code and get in touch with the appropriate Wi...

Page 17: ...customer service Machine switches off and displays Err 6 Fault inside machine or water drain is clogged Notify Winterhalter customer service or remove cause of clogging Machine switches off and displ...

Reviews: