Assembly instructions
|
89014664; 2022-04
|
3
4
Install conductance-controlled dosing device
NOTE
Danger of rusting and clogged jets caused by drilling swarf!
Rusting drilling swarf can also cause “stainless steel” to begin to rust.
Ø
Remove drilling swarf from the interior of the warewasher.
4.1
Install measuring electrode
54
90
1
Ø
Open door.
Ø
Remove the lower wash arms and filter cassette.
Ø
Line the interior of the tank with cloths or suitable paper to catch drilling swarf.
Ø
Determine the size of the drill hole according to the measuring electrode.
Ø
Drill a hole for the measuring electrode at position (1).
Ø
Deburr the drillhole.
Ø
Remove drilling swarf from the interior of the warewasher.
Ø
Install measuring electrode.
Ø
Lead the connection cable of the measuring electrode to the dosing device.
4.2
Assemble injection hose for dosing device for powder
150
2
70
150
2
70
CTR R-L
CTR L-R
Ø
Open door.
Ø
Remove the lower wash arms and filter cassette.
Ø
Line the interior of the tank with cloths or suitable paper to catch drilling swarf.
Ø
Determine the size of the drill hole according to the flushing nozzle.
Ø
Drill a hole for the inflow point at position (2).
Ø
Deburr the drillhole.
Ø
Remove drilling swarf from the interior of the warewasher.
Ø
Mount the flushing nozzle on the warewasher.
Ø
Fasten the injection hose to the flushing nozzle with a hose clamp.
Ø
Seal openings in cover and attach edge protection.