WINTACT WT8807 Instruction Manual Download Page 3

-01-

Ⅰ. 

Introduction

    

Carbon Dioxide Monitor adopts high-quality gas sensors,which displays 

safety and reliability with accurate measurement and stable performance. 
It has excellent sensitivity and repeatability, easy to use and maintain, and 
meets the requirements by safety monitoring in industrial site for high 
reliability of the equipment. The shell is made of high-strength engineering 
plastics and compound non-slip rubber, dust and explosion-proof, with high 
strength and smooth handfeel.
    Carbon Dioxide Monitor is widely used in petroleum, chemical, 
environmental protection, metallurgy, refining,  gas transmission and 
distribution, biochemical medicine, agricultural research,etc.

To know and understand relation between carbon dioxide concentration 
and human physiological reaction:
350-450ppm: the same as general outdoor environment
350-1000ppm: fresh air and; smooth breath
1000-2000ppm: turbid air; feel sleepy
2000-5000ppm: headache, sleepiness, dull, heartbeat accelerating and 
                           lightly nauseous and be unable to concentrate
Over 5000ppm: severe hypoxia, permanent brain damage,coma and 
                           even death

. Safety instruction

For your safety, please read this manual before operation.

      :This operation may induce physical hazard to users. Please be careful.

      :This operation may cause damage to the instrument.Please be careful.

        Warning!

If there is explode accident happening:

      Cut off all the potential gas resource.

      Keep the rescuing area ventilated and no potential combustible  gas 

      existing.

      Switch off all the power connection.

      Evacuate all the people in the area.

      Report to the authorities immediately.

      In daily work, please keep the work environment ventilated,for good 

ventilation can ensure that combustible gas will not accumulate.

B

C

D

E

2

3

4

5

6

VER.A0

1

A

DOCUMENT NO.:   QR-208/A

B

C

D

E

SCALE 

SIZE

DATE

NAME

APPROVALS

APP.       BY

CUSTOMTER 

DRAWN BY

CHECKED BY

1:1

A4

次号

1.

2.  

3.

SHEET

PART Number: X-XXX-XXX-XX

2

3

4

5

6

1

WT8807 WINTACT

唛英文说明书示意图

日期

71688807002

WDJ

2021

-

06

-

19

SHENZHEN WINTACT ELECTRONICS CO.,LTD.

OF

1

1

A

1

1

0

.0

0 m

m

80.00 mm

71688807002
WT8807 WINTACT

唛英文说明书

材料:

105G

双铜; 

页数:
成品尺寸:

80*110mm

公差:±

1

.

0mm

印刷处理:四色双面印刷
装订成册说明书 骑马钉

16P (

封三、页码

12

为空白页

)

Summary of Contents for WT8807

Page 1: ...Carbon Dioxide Monitor Instruction Manual WT8807 MODEL WT8807...

Page 2: ...02 Features 02 Name of parts 03 Operation manual 04 1 Main Menu Interface 04 2 Real time Measurement Interface 05 3 Record Checking Interface 05 4 Alarm Setting Interface 08 5 System Settings Interfa...

Page 3: ...physiological reaction 350 450ppm the same as general outdoor environment 350 1000ppm fresh air and smooth breath 1000 2000ppm turbid air feel sleepy 2000 5000ppm headache sleepiness dull heartbeat a...

Page 4: ...arge the gas detection alarm at the inspection site to avoid fire or explosion caused by the spark generated by the plug in charger 2 Please do not disassemble replace or replace the sensor in an expl...

Page 5: ...y USB charging interface Power Back button Left button Right button Enter button Buzzer alarm hole Gas sensing hole short press to return Left button left forward upward decrease Right button right fo...

Page 6: ...be too low the instrument will start 10s countdown for automatic shutdown The countdown second will be displayed on the left side of the battery indicator After the countdown is over the instrument wi...

Page 7: ...te shows more urgency and faster frequency than that of low alarm state 5 The alarm has two forms light flashing alarm and sound alarm which can be turned on off in the alarm setting 6 The lower left...

Page 8: ...ges For example the green bar graph with 53 in the figure indicates that 53 values in the recorded data are between 549 and 609 The maximum minimum and average value of recorded data are displayed on...

Page 9: ...tton and button to input the serial number to be deleted select OK and press button After that the data within the range of serial number will be deleted Page selection interface Figure 3 Record Check...

Page 10: ...setting and reset default 2 The language can be Chinese or English date and time can be set as year month day hour minute if auto storage is on the measured data will be automatically saved according...

Page 11: ...Accuracy Response time 90 LP103450 1800mAh About 4 hours DC 3 7V Lithium battery capacity 1800mAh Working voltage Battery Model Charging time Standby time 71 153 49mm 215 4g with battery and back but...

Page 12: ...ise it may result in inaccurate test results or damage to the instrument 4 Do not store the instrument in the following environments a Places that may have water or heavy dust b The instrument must no...

Page 13: ...le Carbon Dioxide Monitor Contain Alligator clips TIPS This device is equipped with rechargeable battery If you receive the product and cannot start up please connect with the adapter for charging bef...

Page 14: ...Version WT880 EN 00 7...

Reviews: