WINTACT WT63B Instruction Manual Download Page 5

MENU

F.Preparation for measurement

1. Install batteries;

   Put batteries into battery compartment correctly, 
paying attention to the polarity of battery. 
Press “       ” button to turn on the meter, after powering on, 
check battery status. If power is low, please replace 
battery in time.

2. Select probe for measurement;

   Based on measurement requirements, 
users can select different probes. Measuring 
with different probes may yield different 
evaluations on measurement results.

a. Measure with short (S) probe:
   This probe is installed randomly and 
suitable for a wide range of vibration 
measurements with better response values.

b. Measure with long (L) probe:
   This probe is an accessory in the package 
and is mainly used on narrow or special 
objects with faster response.

c. Remove hardware probe 
to measure: this way is for 
measurement on flat object 
surface with stable data.

6

1.Power on / off

Short press “        ”button to power on, long 
press“        ”button to shut down.

2. Screen rotation

After powering on, press “        ” button to rotate screen. 
Only acceleration measurement, speed measurement, 
displacement measurement and full display interface support 
screen rotation. Each rotation will clear cached data.

3. Full display measurement

Press “        ” to turn on the meter, full display interface 
appears after powering on; short press“          ” to switch 
between high frequency and low frequency mode. Long 
press“          ”button or short press “            ” button to start 
automatic measurement, short press again to exit 
measurement. When cached data is over 0, press“        ”to 
save and window prompt pops up to indicate successful 
operation, then press “        ”button to OK storage.
(The cache can hold up to 20 data, and the first data will be 
automatically removed if the cache is more than 20; the 
maximum data storage is 7 groups, and there will be a 
prompt when storage is full.)

MENU

MEAS

MEAS

MENU

MENU

SAVE

OK

LO/HI

OK

G.Operation instruction

7

52%

20Hz~1KHz

Mode:Lo Freq

12.8

2

m/s

30.2

mm/s

0.112

mm

Menu

52%

1 Hz~10KHz

K

Mode:Hi Freq

10.3

2

m/s

30.2

mm/s

0.112

mm

Menu

Short (S) probe 
measurement

Long (L) probe 

measurement

Remove hardware 

probe measurement

Full display interface 
(low frequency mode)

Full display interface 
(high frequency mode)

Summary of Contents for WT63B

Page 1: ...Instruction Manual of Vibration Meter MODEL WT63B Version WT63B EN 00 Executive Standard Q HTY 008 2018...

Page 2: ...act high temperature and water immersion 4 Take out batteries if not in use for a long time 5 Install batteries in correct polarity replace batteries when the power is low 6 Do not disassemble this me...

Page 3: ...lor display 1 second 1 5V AAA battery 2 0 40 30 90 RH 180x54x30mm 250G with batteries 7 groups D Technical parameters Power indicator Double measurement button Flashlight Screen brightness Select Chin...

Page 4: ...tion settings and make selection Buttons Names of parts Function Description SAVE LO HI MEAS MENU OK MEAS 4 52 Accelerate Velocity Distance File Settings Calibration Back 3 Menu interface description...

Page 5: ...press button to rotate screen Only acceleration measurement speed measurement displacement measurement and full display interface support screen rotation Each rotation will clear cached data 3 Full di...

Page 6: ...e previous screen MENU OK MENU 9 52 0 0mm s mm s Max 0 0 Acc t 0s Min 0 0 Dec t 0s Avg 0 0 Dif 0 0 1 2 3 4 5 s 0 5 0 4 0 3 0 2 0 1 Menu Mode Lo Freq 20Hz 1KHz 6 Speed measurement Enter menu interface...

Page 7: ...automatic shutdown time from 0 min to 9 mins 0 min means that automatic shutdown is prohibited e Restore factory settings Users can choose whether to restore factory settings f Machine grade four lev...

Page 8: ...nter file interface and operation also needs some response time It is recommended to delete some unnecessary data 3 When acceleration value is beyond measurement try to switch frequency 4 The meter wi...

Reviews: