Winsen ZE07-CO User Manual Download Page 4

Zhengzhou Winsen Electronics Technology Co., Ltd                     

www.winsen-sensor.com

 

 

 

Tel: 86-371-67169097/67169670      Fax: 86-371-60932988                            Email: 

[email protected]

 

 

Pin Description

 

PIN15 

Vin

Voltage input 5V-12V

 

PIN5

PIN14 

GND 

PIN1 

VOUT(Voltage output 3.0V) 

PIN3 

Reserved 

PIN4 

Reserved 

PIN7 

UART (RXD) 0~3.0V Data input 

PIN8 

UART(TXD) 0~3.0V Data output 

PIN9 

Sensor analog signal 

PIN10 

DAC 0.4V-2V (0 - full range) 

PIN2/  PIN6/  PIN11/ 

PIN12/ PIN13 

NC 

                                                                                                                            Fig 2 Pins Diagram

 

Communication Protocol 

1. General Settings 

Table 3

 

Baud Rate 

9600   

Data Bits 

Stop Bits 

Check Bits 

Null 

 
2. Communication Commands 

There  are  two kinds  of  communication, initiative  upload mode  and  question  &  answer  mode.  We   

take  initiative  upload mode  as  the  default  settings. The  module  upload  a  gas  concentration  value   

every  1S,  and  the  command  line format  is  as  follows:   

Table  4

 

Gas concentration value = (Byte4*256+Byte6) x 0.1 

 

 

Byte 0 

Byte 1 

Byte 2 

Byte 3 

Byte 4 

Byte 5 

Byte6 

Byte 7 

Byte 8 

Start Byte 

Gas Type 

Unit 

No. of 

decimal 

Concentration 

(High Byte) 

Concentration 

(Low Byte) 

Full Range 

(High Byte) 

Full Range 

(Low Byte) 

Check sum 

0xFF 

CO=0x04 

ppm=0x03 

1= 0x01 

0x00 

0x25 

0x13 

0x88 

0x25 