WiNRADiO G315 VHF/UHF Receiver
66
The difference between
Hit Counter
and
Time on Air
displays can be best
understood if you consider a situation where there was only a single hit in the
scanned band: Using the
Hit Counter
, there will be always one bar displayed,
and will remain of the same (maximum) height, no matter how long you leave
the program running. With
Time on Air
, the height of the bar will decrease
progressively with each new scan.
If there is an active signal on a particular frequency, the respective bar will turn
red for the rest of the scan. This is designed to give you a visual idea of
current activity in the band.
Signal Strength Logger
The
Logger
makes it possible to record signal strength on several discrete
frequencies over a period of time. Up to 50 separate frequencies can be
monitored and you can also specify the sampling interval.
To set up logging for a particular frequency, press the
Add
button and the
following window appears:
Atten
and
Preamp
buttons specify the required state of the
Attenuator
or
Preamplifier
for each trace.
Peak
and
RMS
refer to the S-meter measurement
mode as they exist in the main panel. Each trace can have a different color, to