4-7
SECTION 4 –
APPLIANCES AND SYSTEMS
2. Move SYSTEM switch from Off to Heat and
set the desired temperature using the Temp
Selector slider.
3. Furnace fan should start to blow immediately
after setting the thermostat.
4. After about 30 seconds, the furnace burner
should light.
5. The furnace should now cycle off and on
automatically as the thermostat demands just
like a household furnace.
NOTE: If heat does not come out of the heat
ducts after a minute or so the burner is
not lit.
Turn thermostat off for 3-5 minutes,
check to be sure propane gas tank valve
is open and tank is not empty, then try
steps 2-4 again.
If the furnace will not light after three
attempts, go to Shut Down steps and
contact your dealer or a local RV service
center for repair.
To Shut Down
1. Slide thermostat switch to Off position.
2. Close propane tank valve if coach will be
stored for a period of time.
Further Information
Please see the furnace operating instructions
provided in your InfoCase for further
information, including operating precautions,
and periodic maintenance. See the Coach
Maintenance Schedule for recommended
intervals.
NOTE: If the furnace burner has any residuals
of metal protectant or lubricants used
during manufacture of the furnace, it
may smoke slightly when the furnace is
used for the first time and may set off
your smoke alarm.
We recommend that you provide
adequate ventilation when using the
furnace for the first time to avoid a
nuisance smoke alarm.
We do not recommend removing the
smoke alarm battery.
DUCTED ROOF AIR
CONDITIONING SYSTEM
The furnace thermostat also controls ducted
roof air conditioner operation when the
Thermostat switch is placed in “Cool” position.
All cooling functions controlling to setpoint
have a short cycle protection time delay of three
minutes. There will be no delay if the cycle OFF
time exceeds three minutes.
NOTE: The ducted roof air conditioning system
has ceiling registers that can be closed if
necessary to force more cool air toward
a specific area of the coach or to route
cool air away from a specific area. If too
many vents are closed, however, it can
cause the air conditioner unit to shut
down, particularly in high humidity
conditions.
Further Information
Refer to the manufacturer’s user guide
provided in your InfoCase for complete operating
instructions.
AIR CONDITIONER FILTER
The washable foam air conditioner filter is
located in the ceiling-mounted return A/C grille
in the lounge area of the coach.
Temp Selector
•Slide to select temperature