SECTION 10 -
SLIDEOUT ROOMS AND LEVELING
10-8
•
Use a 3/4” socket and ratchet wrench on the
motor gearbox shaft to crank the room in or
out as needed. Crank both sides of the room
alternately and equally to avoid wedging the
room.
If help is available, a second person (with a
duplicate socket and ratchet) cranking the
other end simultaneously will greatly speed
up the process.
•
Crank the room until it is just “snugged up.”
Do not overcrank or you could damage the
gear assembly.
•
While maintaining pressure on ratchet
wrenches, re-engage the motor brake by
moving lever clockwise slightly (to right
when facing end of motor).
•
Reconnect motor power lead to wiring
harness.
•
Fasten slideout room travel latching device (if
equipped) inside the coach before driving the
vehicle.
•
See your dealer for service of the slideout
mechanism before using again.
Further Information
See the Slideout Room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION - BEDROOM
-If Equipped
Crank-In Procedure
•
Locate the tools in the right front side storage
compartment - a ratchet wrench, a hex-end
shaft, and an extension shaft. (The ratchet
wrench may be packaged in the InfoCase).
•
Locate the small, round access hole in the bed
base at the foot of the bed.
•
Attach the shaft extension to hex-end shaft
and place the ratchet wrench onto the hex end
shaft, then insert into the hole in the bed base
as shown.
•
The slotted end of the tool must engage with
the pin in the endshaft on the slideout gear
assembly. See arrow in close-up detail.
-Typical View
(if chassis-supplied)