10-5
SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
•
If the batteries and fuses are okay, there may
be a failure in the hydraulic control system or
electrical system which requires service.
Retract the room using the following
emergency retract procedures and contact
your dealer for service.
SLIDEOUT EMERGENCY
RETRACTION PROCEDURES
Front Slideout Rooms - Emergency
Crank-In Procedure
(If slideout room will not retract using
control switch)
Step 1 - Relieve Hydraulic Line Pressure
•
Open the hydraulic pump slideout solenoid
valves to release hydraulic line pressure and
let fluid bypass into the fluid reservoir.
•
The hydraulic pump is located beneath the
entrance steps. To access the pump, remove
the nut from the underside of the top step ‘lip’
and lift the step upward and remove.
•
The hydraulic pump is equipped with two sets
of hydraulic solenoid valves that control
different systems.
Hydraulic System Control Box
on pump beneath chassis near LH or RH front tire
Hydraulic Pump Access - remove nut from
bolt on underside of step and lift off step
Hydraulic Pump beneath Entry Step