background image

 

2020_02_13                                                                

580261

 

English 

4 Le Pas du Château 

85670 SAINT PAUL MONT PENIT 

TEL: +33 (0)2 51 98 55 64 

FAX: +33 (0)2 51 98 59 07 

Email: 

[email protected]

 

Website: http://www.winncare.fr 

USER MANUAL,  

fixed footboard bed rail 

A671-00 RIGHT RAIL 

A672-00 LEFT RAIL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for A671-00

Page 1: ...h 4 Le Pas du Château 85670 SAINT PAUL MONT PENIT TEL 33 0 2 51 98 55 64 FAX 33 0 2 51 98 59 07 Email info medicatlantic fr Website http www winncare fr USER MANUAL fixed footboard bed rail A671 00 RIGHT RAIL A672 00 LEFT RAIL ...

Page 2: ...0 FIXED RAILS 5 4 USAGE CONDITIONS 7 4 1 FUNCTION 7 4 2 PRECAUTIONS 7 4 3 RESIDUAL RISKS 8 5 MAINTENANCE CONDITIONS 8 5 1 IDENTIFICATION 8 5 2 MAINTENANCE 8 5 3 CLEANING 8 5 4 DISINFECTION 8 5 4 1 OBJECTIVE 8 5 4 2 INDICATION 8 5 4 3 EQUIPMENT 8 5 4 4 TECHNIQUE 9 5 5 SHELF LIFE 9 5 6 GUARANTEES 10 6 SCRAPPAGE CONDITIONS 10 ...

Page 3: ... and performance Consequently adhering to WINNCARE s recommended usage conditions and using original boards and accessories is a condition of upholding the clauses of the guarantee and ensures that the fixed footboard bed rail is used safely 1 TRANSPORT CONDITIONS During transport rails should be strapped and protected by packaging NB stacking packages on the rail is completely prohibited 2 STORAG...

Page 4: ...671 00 A672 00 AL A671 00 A672 00 MS ML A671 00 A672 00 AE A671 00 A672 00 AF A671 00 A672 00 AG A671 00 A672 00 AH A671 00 A672 00 AX A671 00 A672 00 XA A671 00 A672 00 XB A671 00 A672 00 Beds compatible with the FIXED RAIL Fixed rail Foot of the bed Head of the bed Folding rail The fixed rail is not compatible with DUO 140 160 beds or the PITCHOUNE KALIN bed The fixed rail is not compatible with...

Page 5: ... 3 1 Assembling and installing the A671 00 A672 00 fixed rails Using a 13 mm socket wrench remove the board mount and replace with the new part Attach the footboard to the bed Bed rail lock mechanism 1 2 ...

Page 6: ...6 Attach the fixed rail to the bed Attach the screw and the plastic nut to lock the rail in place 3 4 ...

Page 7: ...head neck or chest When deciding whether or not to use the fixed footboard bed rails a risk benefit ratio assessment should be first be performed This assessment should take account of the department s monitoring ability A standardized institutional protocol for using the fixed footboard bed rail can be prepared the patient s physical and mental health their needs abilities lucidity size and level...

Page 8: ... avoid transmitting bacteria from one patient to another Remove any organic substance via Mechanical action scrubbing Chemical action disinfection 5 4 2 Indication Rails are physically and bacteriologically clean 5 4 3 Equipment Microfibre wipes Detergent or Detergent Disinfectant CE marked Surface DD and Surface Disinfectant Chlorine derivatives 30 alcohol NB undiluted DD products and bleach shou...

Page 9: ...actuators electrical components and remote controls with microfibre wipes soaked with disinfectant Do not rinse or dry Check for normal function and the various operations Repair if necessary NB Take the measures recommended by the hospital s internal hygiene department in case of additional precautionary measures Contact Droplets Air precautions Using a greater than 5000 ppm bleach solution 0 5 a...

Page 10: ... label Replacement is made by providing original parts within the limit of the guarantee period with our resale network determining the start of the guarantee period Returning defective parts is mandatory so that the guarantee can be applied correctly and to avoid receiving an invoice 6 SCRAPPAGE CONDITIONS The product must be scrapped if it no longer meets the essential requirements particularly ...

Page 11: ...11 ...