USER MANUAL
APPENDIX B
MIL-STD-810E/F COMPLIANCE
76
MILITARY RACK MOUNT PANEL PC
APPENDIX B: MIL-STD-461E/F COMPLIANCE
This section includes information on testing methods and procedures in compliance with
military standard MIL-STD-461 E/F.
MIL-STD-461E/F Compliance
Test
Description
Type
Frequency
Range
CE101
Power Leads
Conducted Emission
30 Hz ~ 10 kHz
*CE102 Power Leads
Conducted Emission
10 kHz ~ 10
MHz
CS101
Power Leads
Conducted Susceptibility
30 Hz ~ 150
kHz
CS109
Structure Current
Conducted Susceptibility
60 Hz ~ 100
kHz
CS114
Bulk Cable Injection
Conducted Susceptibility
10 kHz ~ 200
MHz
CS116
Damped Sinusoidal Transients,
Cables and Power Leads
Conducted Susceptibility
10 kHz ~ 100
MHz
RE101
Magnetic Field
Radiated Emission
30 Hz ~ 100
kHz
*RE102 Electric Field
Radiated Emission
10 kHz ~ 18
GHz
RS101
Magnetic Field
Radiated Susceptibility
30 Hz ~ 100
kHz
RS103
Electric Field
Radiated Susceptibility
2 MHz ~ 18
GHz
*Default Test