background image

8

1. DMX LED should be on. If not, check DMX connectors, cables to see if link

properly.

2. If the DMX LED is on and no response to the channel, check the address settings and

DMX polarity.

3. If you have intermittent DMX signal problems, check the pins on connectors or on

PCB of the unit or the previous one.

4. Try to use another DMX controller.

5. Check if the DMX cables run near or run alongside to high voltage cables that may cause

damage or interference to DMX interface circuit.

C. One of the channels is not working well

1. The stepper motor might be damaged or the cable connected to the PCB is broken.

2. The motor’s drive IC on the PCB might be out of condition.

5. Fixture Cleaning

The cleaning of internal and external optical lenses and/or mirrors must be carried out

periodically to optimize light output. Cleaning frequency depends on the environment

in which the fixture operates: damp, smoky or particularly dirty surrounding can cause

greater accumulation of dirt on the unit’s optics.

Clean with soft cloth using normal glass cleaning fluid.

Always dry the parts carefully.

Clean the external optics at least every 20 days. Clean the internal optics at least

every 30/60 days.

Summary of Contents for COB200W 2in1 WW+CW led Par Light

Page 1: ...1 COB200W 2in1 WW CW led Par Light User manual Please read the instructions carefully before use ...

Page 2: ...unit to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the unit Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow green conductor to earth in order to avoid electric shock The unit is for indoor use only Us...

Page 3: ...ration as high voltage might be causing electric shock Warning To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture DO NOT open the unit within five minutes after switching off The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged Caution There are no user serviceable parts inside the unit DO NOT open the housi...

Page 4: ...strobe Variable electronic dimmer 0 100 and 4 type in optional LED operation menu with function buttons Reset to factory settings option Color temperature setting Build in program with speed adjustment 16 bit dimmer effect and White balance Temperature sensor via software to control fans speed against overheat Different DMX channel mode Including STAG ARC1 AR1D ARC2 AR2D AR2S and HSV Control DMX C...

Page 5: ...mming functions DOWN To go backward in the selected functions uP To go forward in the selected functions ENTER To confirm the selected functions Set DMX Address Code 1 Press Menu to Set DMX Address and press ENTER keys to enter into 2 Show Set DMX Address DMX Address A001 Press the UP and DOWN keys to amended 3 Press ENTER keys to save and Exit Press the MENU Keys does not save and Exit Menu The d...

Page 6: ...g Ho oF DMX Signal loss processing mode Ho Hold the final DMX signal state oF Close all LED 5 u255 WW Dimmer 000 255 Warm White Dimmer Dark to Bright 6 C255 CW Dimmer 000 255 Cold White Dimmer Dark to Bright 7 F255 Strobe 007 255 UP DOWN change the speed 8 CC15 Colors Jump 00 15 UP DOWN change the speed 9 DE15 Colors Gradate 00 15 UP DOWN change the speed 10 CP15 Colors Pulse 00 15 UP DOWN change ...

Page 7: ...00 050 CH1 CH6 Control 051 100 Different Colors output 101 150 Colors Jump Change 151 200 Colors Gradate 201 250 Colors Pulse Change 251 255 Sound Active CH6 Function Speed Slow to Fast At the Colors output choose the color 4 Trouble shooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The unit does not work no light and ...

Page 8: ...he channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 5 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp s...

Reviews: