background image

English

ZERO+ WiFi

INSTALLING THE FILTERS 

Ÿ

Install the filters until they fit securely in 
place.

Filters must be installed in this order:

 3 

 True HEPA filter with Cleancel™ 

(rear)

 2 

 CD Carbon filter 

(middle)

 1 

 Pre-filter 

(front)

 

ˍ

To install the pre-filter, insert bottom tabs 
into the slots on either side of the lower part 
of the unit, then rotate upward to insert the 
upper tabs into the slots at the top part of 
the unit until both sides audibly click into 
place.

Pre-filter 

CD Carbon 
filter 

True HEPA
filter with
Cleancel™

Ź

Replace the front panel by first inserting 
the latch at the bottom edge into the 
base of the unit, then rotate the panel 
upward toward the top of the unit until it 
magnetically snaps closed.

ź

When to service and replace filters:

Filter

Indicator Light

When to 

service

When to 

replace

 1 

 Pre-filter

none

Clean once every 

14 days

Permanent

 2 

 CD Carbon filter

Can NOT be 

WASHED

Lasts up to 

6 ~12 months

 3 

  True HEPA filter 

  with Cleancel™

ę

 Intervals between filter replacement may vary depending on environment.

ę

  For optimal use, Pre-filter can be cleaned every 14 days which can extend the life of 
 other filters.

this unit

is compatible

with this 

ĆOWHU

FILTER

ITEM: 117130

J

Summary of Contents for ZERO+

Page 1: ...ide Please read and follow all safety rules and instructions in this manual before operating The product warranty is printed on the back of this guide so please keep it in a safe place for future use...

Page 2: ...oooooooooooooooooooo13 FILTER CARE oooooooooooooooooooooooooooooooooooooooooooooooooooooooooo15 PARTICLE SENSOR CARE ooooooooooooooooooooooooooooooooooooooooooooooo19 CLEANING CARE ooooooooooooooooooo...

Page 3: ...ial coated 5 Product User Manual 1 5 385 5 52 L L 38 User Manual Model Use Care Guide Please read and follow all safety rules and instructions in this manual before operating The product warranty is p...

Page 4: ...PlasmaWave Indicator Indicates whether PlasmaWave is enabled or disabled Timer Air Quality Button Press to cycle through and set desired length of operation 1hr 4hr 8hr NO TIMER Press and hold for 3 s...

Page 5: ...the risk of serious injury or death and to reduce risk of damaging the unit Do not use around mist or fumes from industrial oil or around large quantities of metallic dust Do not place around heating...

Page 6: ...ned Remove the front panel by grasping its upper edge and gently pulling towards yourself To remove the front panel the latch at the lower edge of the panel must be released from its position Latch Re...

Page 7: ...HEPA filter with Cleancel Replace the front panel by first inserting the latch at the bottom edge into the base of the unit then rotate the panel upward toward the top of the unit until it magnetical...

Page 8: ...or death and to reduce risk of damaging the unit Do not pull on the power cord when unplugging the unit Do not tie or knot power cord when unit is in operation If the unit becomes submerged in water...

Page 9: ...unit first powers on the mode will be set to Auto with PlasmaWaveh enabled When in Auto Mode the fan speed will be automatically adjusted according to the environments air quality PlasmaWaveh works to...

Page 10: ...uto Mode the fan speed is automatically adjusted according to the indoor air quality As the indoor air quality improves the fan speed will automatically be reduced If the indoor air quality decreases...

Page 11: ...l Mode is in use Auto and Sleep modes are automatically disabled 4 Timer The timer can be set for when you want the unit to run for a specified period of time Select the desired period by pressing the...

Page 12: ...ld the Child Lock button again for 3 seconds 3 seconds 7 Air Quality LED Light The Air Quality LED light may be turned on or off To turn the Air Quality LED light on or off press and hold the Timer bu...

Page 13: ...router must be installed within range of the air purifier to use WINIX SMART Ensure Wi Fi router matches the following specifications 802 11b g n 2 4GHZ or for a dual band wireless router 2 4GHz 5GHz...

Page 14: ...o connect to this model Read the notice and select OK Enter the password to your Wi Fi network Press and hold the Wi Fi button on the unit s control panel until it beeps The Wi Fi strength indicator w...

Page 15: ...s Filter Indicator Light When to service When to replace 1 Pre filter none Clean once every 14 days Permanent 2 CD Carbon filter Can NOT be WASHED Lasts up to 6 12 months 3 True HEPA filter with Clean...

Page 16: ...nd gently pulling towards yourself To remove the front panel the latch at the lower edge of the panel must be released from its position Latch Press the tabs on the top edge to remove the 1 Pre filter...

Page 17: ...True HEPA filter with Cleancel Insert the 1 Pre filter front To install the pre filter insert bottom tabs into the slots on either side of the lower part of the unit then rotate upward to insert the u...

Page 18: ...olatile substances such as alcohol or acetone If the pre filter becomes damaged or in any way needs replacement Please contact your local dealer NOTICE Do not use benzene alcohol or other volatile flu...

Page 19: ...it is running in a place with high dust levels Open the Particle Sensor cover Use a damp cotton swab to wipe the lens and intake area of the Particle Sensor To clean the sensor area use only water Do...

Page 20: ...the interior Open the front panel and clean the interior with a vacuum cleaner For optimal performance clean the interior 1 2 times a month NOTICE When cleaning the unit always unplug the power cord f...

Page 21: ...electrical equipment are working and try again It doesn t work in Auto mode Has Auto mode been selected Press the Mode button until Auto mode is selected Is the sensor blocked or clogged Clear the se...

Page 22: ...There is a strange smell Is it being used in a place with a lot of smoke dust or odors Clean the air intakes on the front sides of the unit and clean the pre filter Contact customer service to confir...

Page 23: ...tage AC220 240V 50 60Hz Power Rate 90 W Max Room Capacity 120 m2 Dimensions 415 mm W x 245 mm D x 600 mm H Weight 8 5 kg Replacement Filter LOWHU LWHP Pre Filter 3DUW The exterior design and product s...

Page 24: ...nsumer shipping and service fees may be incurred even during the warranty period The warranty must be presented upon bringing the product for service Store the warranty in a safe place as it cannot be...

Page 25: ...Contact your local dealer for product related inquiries and customer service WWW WINIX COM EU 2610 0169 00 Rev 00...

Reviews: