Marine Installation Manual
2021-08
3-9
3 Engine Installation
3.4 Platform arrangement
X72DF
3.4
Platform arrangement
3.4.1
Drawings
For platform arrangement see the links given in section
3.4.2
Minimum requirements for escape routes
The platforms shown in the relevant drawings are arranged in such a way as to
ensure safe escape routes for the crew. The minimum sizes required by the clas
-
sification societies are met.
Figure 3
-
3 Minimum requirements for headroom
Important!
•
The minimum sizes are to be taken into account when installing the engine.
Special attention is to be given to the minimum distance between the ship’s
platform and the lower engine platform, to ensure sufficient headroom (see
).
•
No dead ends may be created on the platforms by shipboard installations. If
a dead end cannot be avoided, then a passage leading to the ship’s platform
has to be cleared before the dead end (distance from dead end: max.
2,000mm).
See also the links to drawings in section
.
SM-0115
Ship’s platform
Lower platform
h = min. 2000 mm
600 mm
2000 mm
Reference frame