VERSION 3
05/01/2021
I
NSTALLATION AND
U
SAGE
G
UIDE
WINESP40DUPRO
Page 13
3
INSTALLING THE WINEMASTER® AIR CONDITIONER
3.1
LIST OF EQUIPMENT REQUIRED
-
4G1.5mm² cord for connecting the outdoor unit
-
3G1.5mm² cord for connecting the connections housing
-
1/4" and 3/8" copper pipes for refrigeration connections
-
Fasteners and tools for fastening the outdoor unit
3.2
PUTTING IN PLACE THE OUTDOOR UNIT
3.2.1
INSTALLATION
Step 3: Fasten the brackets with the
appropriate fasteners.
Step 4: Place the air conditioner
on the brackets.
Step 5: Screw the four M6 bolt and
washer assemblies using a 10 mm key.
Step 1: Mark out and drill the
fastening holes as indicated.
(Drilling diameter: 12 mm max.)
Step 2: Unfold the brackets.