background image

Cutting the Directional Handle to fit Roof Thickness

Carefully align the keys inside 
the directional handle with the 
keyways on the bottom of the 
gear housing. (The keys only line 
up one way—do not force.)

Pull the handle down, and transfer 
this dimension to the shaft end of 
the directional handle. Mark this, 
and cut the handle at the mark.

Push the directional handle up 
into ceiling and over the shaft. 

Measure the distance between 
the bottom of the recess on the 
handle to the ceiling.

Inside the vehicle, mark the 
elevating shaft 3.8 cm below the 
ceiling. Cut the shaft on this mark. 

Make sure the top of the 
directional handle is snug against 
the bottom of the base plate.

Determine the roof thickness. The mount is designed to fit roofs from 2.5 cm to 12 cm thick. 

• 

If the roof is less than or equal to 12 cm thick, continue to step 2.

• 

If the roof is more than 12 cm thick (max. 17.8 cm), a directional handle extension is needed. 
Winegard recommends model EK-1036 directional handle extension (sold separately).

Do not 
connect high

current devices 
such as hair dryers 
to this receptacle. 
Maximum 
current rating of 
receptacle is 8 
amps at +12 VDC.

The power supply may be flush mounted in most standard electrical boxes. To flush mount, cut a hole in the wall to fit the 
box. Run two #12 wires between the wall plate and +12 VDC source, and route downlead cable to this location.

Select a location for the power supply.

Make 12 volt connection to the power supply. Install terminals on wires from +12 VDC source, and crimp the terminals 
with an appropriate crimping tool. If in doubt as to the polarity of the wires, connect them temporarily to the tabs, and 
press the “ON” switch on front of wall plate; if light comes on, polarity is correct. Turn power off.

Installing the Crank Assembly

Lay the ceiling plate on top of

the directional handle with

the pointers aligned. 

Slide the ceiling plate and 
directional handle assembly over 
the rotating base shaft.

Installing the Crank Assembly, Cont.

1

2

Make pilot holes in the ceiling. 
Then, mount the ceiling plate with 
the four provided screws.

3

TIP

 

The knobs on the 
directional handle 

should fit into the grooves 
on the ceiling plate.

Slide the elevating crank (with 
nylon bearing on top) onto the 
rotating base shaft. 

Check that the set screw lines up 
with one of the flat sides of the 
rotating base shaft.

7

8

Tighten the set screw until it 
touches the rotating base shaft. 

Then, tighten only ¼ turn more

.

9

NOTE

 

The set screw simply holds the elevating 
crank to the rotating base shaft.

Installing the Power Supply

1

2

2

3

4

5

6

7

TIP

 

The pointer on the handle should point 
toward the back of the coach.

The handle cut 
must be flat.

1

The power 
supply

should be turned off 
when connecting 
cables/wires.

5                                                                                             Winegard Sensar HV Antenna

Winegard Sensar HV Antenna                                                                                             6

Front of Power Supply

Back of Power Supply

Pointers

3

4

6

2

5

5

7

Set 

screw

Thick key

3.8 cm 
below ceiling

Cut shaft here

distance x

Cut handle here

distance x

EK-1036

Sold Separately

Remove the backing from the 
decal, and place the decal on 
the bottom of the directional 
handle.

Slide the spring over the rotating 
base shaft.

4

5

Place the nylon bearing over the 
top of the crank.

6

Thin key

Directional 

handle

Summary of Contents for Sensar HV

Page 1: ...rk NSW 2143 Phone 02 9645 7600 Fax 02 9645 7688 Email Technical technical coastrv com au Email Warranty warranty coastrv com au 2452246 For VHF UHF channels Bidirectional antenna Operating dimensions 43 2 cm wide x 116 cm tall Length when stowed 125 3 cm Height when stowed 11 2 cm Storage survival temperature 40 C to 80 C For outdoor use only Model CC 10HV Aftermarket Specifications Product Regist...

Page 2: ...el for best operation must be within three degrees of level For sloped rounded roofs Winegard recommends model RW 2000 exterior roof wedge sold separately to level installation An interior wedge IW 5000 sold separately is also available 1 4 3 2 The Winegard Sensar HV antenna requires a minimum roof space of 125 3 cm x 43 2 cm for the stowed antenna When stowed the top of the element housing rests ...

Page 3: ...ter the elevating shaft in the 4 5 cm diameter hole Check with your vehicle manufacturer to determine if the provided screws are suitable for your roof Temporarily secure the base plate to the roof with two of the provided screws Check that the weather boot is in place over the boot collar Make sure the antenna is in the chosen location The antenna should be in the stowed travel position The coax ...

Page 4: ... and crimp the terminals with an appropriate crimping tool If in doubt as to the polarity of the wires connect them temporarily to the tabs and press the ON switch on front of wall plate if light comes on polarity is correct Turn power off Installing the Crank Assembly Lay the ceiling plate on top of the directional handle with the pointers aligned Slide the ceiling plate and directional handle as...

Page 5: ...signals run a channel scan to find the best signal Rotate the antenna until the pointer on the directional handle aligns with the pointer on the ceiling plate Turn elevating crank counterclockwise in the DOWN direction about 13 turns or until some resistance is noted The antenna is now in the travel position 3 4 Do Don t Check parking location for obstructions before raising the antenna Carefully ...

Page 6: ...out of round Installing Connector on Coax Cable TIP If installing in hot weather increase these dimensions 3 mm Notes Parts Mount Nut Nylon Bearing Gear Housing Nylon Bearing Q Ring Base Plate Plug Worm Gear Mounting Screw Directional Handle Ceiling Plate Crank white Spring Nylon Bearing Screw Decal Directional Handle white Ceiling Plate white ORDERING REPAIR PARTS Repair parts are available at ma...

Page 7: ...e Plate 1 Nylon Bearing for base plate 1 Mounting Screw 10 Light Gray Boot 1 RP 5895 Crank Ivory RP 6795 Crank White Part Description Quantity Part Description Quantity Crank ivory 1 Crank white 1 RP 6200 Directional Handle Ceiling Plate Ivory RP 6300 Directional Handle Ceiling Plate White Part Description Quantity Part Description Quantity Spring 1 Spring 1 Decal 1 Decal 1 Ceiling Plate ivory 1 C...

Page 8: ...ance with product instructions or acts of nature such as damage caused by wind lightning ice or corrosive environments such as salt spray and acid rain This Limited Warranty also does not apply if the product becomes unable to perform its intended function in any way as a result of the television signal provider making any changes in technology or service RETURN AUTHORIZATION POLICY A Return Mater...

Page 9: ......

Reviews: