![Wine Guardian 24S025 User Manual Download Page 32](http://html1.mh-extra.com/html/wine-guardian/24s025/24s025_user-manual_986040032.webp)
28
Note installation setup number and setting changed from the factory settings.
Setup Number 3 - Changed to 1
Setup Number 5 - Changed to 9
Setup Number 9 - Changed to 5
Setup Number 12 - Changed to 1
Wiring diagram Fig .6 applies (Conventional 1 heating/1 cooling system with one trans-
former)
The thermostat can receive a battery to light the panel in case of a power failure. It serves no
other purpose and is not required for operation or restart after a power failure.
Time Delays Built Into the Thermostat
Pay attention to the various time delays built into the thermostat as explained in the Thermostat
Installation and Operating Instructions. The time delays are built in to protect the Wine Guard-
ian and its components from damage due to short cycling.
Note
Any time the “cool on” indicator is flashing the unit is waiting for the timer in order to start.
Location of Supply and Return Grilles
Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes
air circulation in the room. Avoid short circulating of the air.
Do Not:
• install the return air grilles directly on the floor as the grilles will collect dust
from the floor.
• locate the supply or return air grille where it is blocked by bottles, boxes or
cases.
• locate the supply air grille where it blows directly on the thermostat.
Relocating a Grille on the Wine Guardian
1) Remove the fasteners from the grille
2) Remove the fasteners from the access door panel to be replaced by the grille
3) Relocate the outlet grille to its new location and secure in place using its fasteners
4) Replace the access door panel where grille was located.
Summary of Contents for 24S025
Page 14: ...10 Wiring Diagrams 24S025 and 24S050...
Page 15: ...11 Wiring Diagrams 24S088 and 24S200...
Page 16: ......
Page 17: ......
Page 38: ......