By pressing the
UP
and
DOWN
button from this interface, you can set the value as follows:
Value
Mode
Function
24h
Normal (Default) Load is supplied continuous power.
1h
– 15h
Timed Control
Load is supplied power at nighttime and continues working
for the specified duration (in hours). For example, if the Load
Control Value is set to 2h, then the load will be turned on at
night time and remain on for a period of 2 hours.
0h
Light Control
Load starts to supply power after dark and stops at dawn
(sunrise).
IMPORTANT:
There is a 10-minute delay before turning on the load in order to make sure it is really dark
and not a passing cloud etc.
3.4.8
RESET Default Setting
By entering this mode, you can reset the controller to its default settings.
By pressing the
UP
and
DOWN
button from this interface, you can select [Yes] and then press
ENTER
to
reset the controller.
IMPORTANT:
All Settings and values are reset when this action is executed and confirmed by “
DONE
”.
3.5 P
ROTECTION
F
EATURES
The P30LF has several built-in protection features, but as stated in the Connection Section of the manual,
external fuse are strongly recommended in the positive lines between the controller and the panel array, the
battery, and the load in order to prevent surge damage. A full system fusing diagram is below