3.3.2 

Parallel Connection 

A parallel connection will increase the system capacity (Ah) and the system voltage will remain unchanged. 
 
For example, if two 12V batteries with 50Ah of capacity are wired in series, the resulting battery bank will be 12V 
of 100Ah (50Ah + 50Ah = 100Ah). 

 

3.3.3 

Series-Parallel Connection 

A Series-Parallel connection will increase the system capacity (Ah) as well as increase the system voltage. 
 
For example, if four 12V batteries with 50Ah of capacity are wired in series-parallel, the resulting battery bank 
will be 24V of 100Ah. 

 

Summary of Contents for BAT-ML12-080

Page 1: ...BattaMax User Manual Revision 2 0 Page 1 of 14 windynation 01 06 2016 BattaMax Absorbent Glass Mat AGM Sealed Lead Acid SLA Batteries BAT ML12 080 BAT ML12 100 User s Manual...

Page 2: ...rallel Connection 8 4 Service and Maintenance 9 4 1 Charging 9 4 1 1 State of Charge SOC 9 4 1 2 Charge Characteristic Curve Standby Use 10 4 1 3 Temperature Compensation 10 4 2 Discharging 10 4 2 1 C...

Page 3: ...hould be referred to qualified service personnel Remove all sources of power photovoltaic wind generator battery chargers etc before servicing or installing Battery Safety Warning Batteries can produc...

Page 4: ...er 9 Electric Vehicles 2 3 SPECIFICATIONS 2 3 1 Electrical Specifications Parameter BAT ML12 080 BAT ML12 100 Nominal Voltage 12V 6 cells Nominal Capacity 20hr 1 80V cell 25oC 85 Ah 106Ah Nominal Capa...

Page 5: ...or burns Do not disassemble heat above 70 C 160 F or incinerate 3 1 ENVIRONMENT Batteries should be installed in a clean dry well ventilated area keeping water oil and dirt away from the batteries Th...

Page 6: ...ll not exceed 0 2 volts To ensure proper connections please use the wire gauge reference in Sec 3 2 1 Please note UL and NEC electrical cable amperage ratings are lower than the chart below 3 2 1 Wire...

Page 7: ...07 in lbs 11 12 Nm 3 2 2 3 Terminal Protection Corrosion can build up on terminals if they are not kept clean and dry To prevent corrosion apply a thin coat of terminal protector spray that can be pur...

Page 8: ...xample if two 12V batteries with 50Ah of capacity are wired in series the resulting battery bank will be 12V of 100Ah 50Ah 50Ah 100Ah 3 3 3 Series Parallel Connection A Series Parallel connection will...

Page 9: ...hat higher charge voltage to charge the battery quickly and safely Once the battery is fully charged a somewhat lower voltage is applied to maintain the battery in a fully charged state Important Batt...

Page 10: ...battery capacity should be 100Ah This will limit the average depth of discharge to 50 and will extend the life of the battery as shown below 4 2 1 Constant Current Discharge Amperes at 25oC 77oF 5min...

Page 11: ...ng but periodic inspections and parameter recording will ensure effective operation and identify issues before they become problematic 1 Examine the outside appearance of the battery The tops of the b...

Page 12: ...and ordinances must be followed Lead acid batteries have fortunately been an environmental success with more than 98 of all battery lead being recycled Batteries are at the top of the list as one of t...

Page 13: ...part s ii to repair the reported problem or iii to refund the purchase price of the Product Repaired or replaced products are warranted for the remainder of the original warranty period only No emplo...

Page 14: ...R PERFORMANCE OF THE PRODUCTS WILL MEET YOUR REQUIREMENTS OR THAT YOU WILL BE ABLE TO ACHIEVE ANY PARTICULAR RESULTS FROM USE OR MODIFICATION OF THE PRODUCTS Some jurisdictions do not allow the limita...

Reviews: