GROUNDING INSTRUCTIONS
T1 98648 03/27/00
4
THIS PRODUCT IS FOR COMMERCIAL USE ONLY.
ELECTRICAL:
In the USA this machine operates on a standard 15 amp
115V, 60 hz, A.C. power circuit . The amp, hertz, and
voltage are listed on the data label found on each machine.
Using voltages above or below those indicated on the data
label will cause serious damage to the motors.
EXTENSION CORDS:
If an extension cord is used, the wire size must be at least
one size larger than the power cord on the machine, and
must be limited to 50 feet (15.5m) in length.
GROUNDING INSTRUCTIONS:
This appliance must be grounded. If it should malfunction
or break down, grounding provides a path of least
resistance for electric current to reduce the risk of electric
shock. This appliance is equipped with a cord having an
equipment-grounding conductor and grounding plug. The
plug must be inserted into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
This appliance is for use on a nominal 120-volt circuit, and
has a grounded plug that looks like the plug in “Fig. A”. A
temporary adaptor that looks like the adaptor in “Fig . C”
may be used to connect this plug to a 2-pole receptacle as
shown in “Fig. B”, if a properly grounded outlet is not
available.
The temporary adaptor should be used
only until a properly grounded outlet (Fig. A) can
be installed by a qualified electrician. The green
colored rigid ear, lug, or the like extending from
the adaptor must be connected to a permanent
ground such as a properly grounded outlet box
cover. Whenever the adaptor is used, it must be
held in place by a metal screw.
Improper connection of the equipment-grounding con-
ductor can result in a risk of electric shock. Check
with a qualified electrician or service person if you are
in doubt as to whether the outlet is properly grounded.
Do not modify the plug provided with the appliance - if
it will not fit the outlet, have a proper outlet installed by
a qualified electrician.
PROPER GROUNDING
NOTE: In Canada, the use of a temporary adaptor is not
permitted by the Canadian Electrical Code
Grounded
Outlet
Grounding Pin
Fig. A
!
WARNING
Metal Screw
Adaptor
Grounded Outlet
Box
Fig. B
Fig. C
Tab For Grounding Screw
Adaptor