Maintenance
unplug machine at mains
outlet before dismantling any part of machine
If red light (d) shows, change paper filter bag.
To do this first pull cover release (5) picture 1
forward and lift the cover from the dust bag
housing. Slide the dust bag sealing plate (28)
from the holder (29). Slide the sealing plate
(28) of a new bag into the holder and push
firmly in. Insert cover into dust bag housing,
push it forward then lock it in place by pushing
down the cover release (5).
The micro hygiene filter (30) needs to be
changed when it becomes clogged with dust
or after approximately 20 paper bags have
been used. To change the hygiene filter first
remove the cover then slide the filter out at the
bottom. To replace lift the lever and slide the
new filter in.
After 20 paper bags have been used also
change the exhaust filter (32). To remove the
exhaust filter push the catch (33) backward
and remove the filter cover (34) and filter.
Insert the new filter and replace the filter cover.
To change the brush roller (35) and the edge
brush
press the release knobs (36 or
pull the bearing block (37) or the brush
cover
outwards. Turn the brush roller
(35) clockwise, and the edge brush (35a) in the
direction of the arrow marked on the end of
the brush, and pull each brush out of the
channel. The new brushes are fitted back into
the channel and onto the drive shafts, both are
turned until they snap into position, then
replace bearing block (37) and brush cover
Underneath the machine is an inspection door
to check for blockages (38).
Blockages-in the neck (20 picture 2) can be
checked by first lifting off the dust bag housing
by pressing the catch (8). Then release the foot
pedal, lower the neck and check into the tube
next to the pedal.
Blockages in the hose can cleared by taking
the hose off the machine and replacing it the
wrong way round in the connecting tube
holding it upright with one hand blocking the
top and switching on the machine. (If
necessary quickly lift your hand on and off the
end of the hose.)
The guarantee is invalidated if take out
parts not approved by WINDSOR. eg. bags,
filters, brush roller, etc. are fitted!
Summary of Contents for SENSOR SR18
Page 5: ...SENSOR SR 18 ...