Brush Deck
The dual cylindrical head is designed to agitate the
carpet while vacuuming. The first scrubbing brush
turns in a clockwise rotation when viewed from the right
of operator's side of machine. The first brush scrubs
dirt and debris between the brushes. The second
brush, turns in a counter clockwise rotation, picks up
debris and throws it into the nozzle.
Maintenance
The brushes should wear evenly side to side. Brushes
should be replaced as a set when bristle length wears
to height of yellow PerformAlertTM bristles.BRUSH
REMOVAL
The brushes are removed from the right side of the
machine.
1. Remove right deck side cover by removing the two
mounting screws.
2. Remove the brush door by removing the three
mounting screws.
3. Slide the brushed out the side opening.
Brush Installation
The front and rear brush are opposite in brush pattern
and must be installed in the correct orientation.
1. Slide brush through door opening and onto drive
shaft. Make sure it is fully seated and is driven by
the deck system.
2. Install the brush door and deck side cover.