Maintenance
Onboard Charger (Optional)
Do not unplug batteries while onboard charger is
active.
Onboard Charger Programming
For machines equipped with optional on-board charger.
When replacing batteries, charger programming
changes may be required. If replacing batteries with
same type, (e.g. maintenance free batteries with main-
tenance free) no programming is required. When
batteries with different type (e.g.maintenance free with
wet cell), programming change are required. Failure to
make programming changes may lead to reduced
battery life.
1.
Remove upper control panel.
2.
Peel back label on charger to access dip switches.
3.
Change switches to correct battery type.
4.
Replace charger label and install upper control
control panel.
1
2
3
4
5
6
7
8
DIP DIP DIP
DIP DIP DIP DIP
DIP
LEAD ACID
DISCOVER AGM
OFF ON
ON
OFF ON ON
OFF
ON
ON OFF OFF
OFF ON ON
OFF
OFF