Do not install and use your air conditioner before completely reading these instructions.
This will help you optimize the operation of your air conditioner.  Make sure that you haven’t
lost the small box placed on the top of the unit; it contains all accessories, which are
essential for use.

„

Each person present  in a room provides
between 100 Watts and 150 Watts of heat.
Consequently, the more people there are in a
room, the less effective the unit will be in
cooling.

„

Blocking of the filter reduces the efficiency
of the air and increases its power
consumption by up to 6%.

„

Avoid opening doors frequently.

1. Your unit must always be used in an
upright position because it contains a
cooling agent.

2.  After unpacking, place the unit upright to
allow the cooling agent to stabilize, and wait
3 hours before use.

Failure to comply with these instructions
may damage the unit and will invalidate the
warranty.

Using your unit in wine cellars or in any
room with a temperature under 61°F is not
recommended.

The following advice and instructions should be followed closely:

IMPORTANT INSTRUCTIONS

ENERGY SAVING TIPS

TECHNICAL SPECIFICATIONS

Cooling Capacity

Power Input

Coolant

Moisture Removal

Airflow Volume

Temperature Range

Voltage/Frequency

Product Dimension (WxHxD)

Product Measurement

Product Weight

Drain Hose Length

Exhaust Hose Length

Exhaust Hose Diameter

Condensation Tank Capacity

12,000 BTU/Hour

1200 Watts / 10Amps

R-22

3 1/2 Pints / Hour (40 Liters / Day)

247 CFM (Cubic Feet / Minute)

61

o

  -

 

90

o

F (16

o

  -

 

32

o

C)

120V/60Hz

18 in (W) x 16 1/2 in (D) x 35 in (H)

460mm(W) x  420mm(D) x 880mm(H)

6 Cubic Feet

Net Weight: 97 lbs. / 44 kgs.

Gross Weight: 118 / 54 kgs.

9 1/2 feet

11 1/2 inches (compressed); Extends up to 5 feet

Inside: 4 3/8 inches / Outside: 5 1/8 inches

2 3/4 Cups (0.65 Liters)

Summary of Contents for PACR12

Page 1: ...PACR12 PORTABLE AIR CONDITIONER INSTRUCTION MANUAL ...

Page 2: ...nit in an upright position before unpacking 2 Slide off the two packing straps DO NOT CUT THEM Save them for future use 3 Slide the carton up and it will release from the base 4 Carefully lift the carton over the unit 5 The remote control unit exhaust tube and accessories are located in the styrofoam on top of the unit 6 Save ALL packaging for off season storage ...

Page 3: ...NS 2 LEARN INTELLIGENT AIR CONDITIONING 2 IMPORTANT INSTRUCTIONS 3 ENERGY SAVING TIPS 3 TECHNICAL SPECIFICATIONS 3 PARTS ILLSTRATION 4 CONTINUOUS DRAIN FEATURE 5 EXHAUST KIT INSTALLATION 6 OPERATING INSTRUCTIONS AND FUNCTIONS 8 CLEANING THE UNIT 10 TROUBLESHOOTING GUIDE 11 PRODUCT LIMITED WARRANTY 12 ...

Page 4: ...yskeepitinanuprightpositiontoavoidany damagetothecoolingsystem Operatethisunitinanambienttemperatureof90o or lower Besurethattheairinletsandoutletsarenotblockedor coveredup Neverplaceanythingontopoftheunitanddonotcover itwithanykindofclothwhile itispluggedinorin use Your air conditioner has been designed to be used onlyinahouse officeandsimilarconditionsandit shouldnotbeusedforanyotherpurpose Neve...

Page 5: ... and wait 3 hours before use Failure to comply with these instructions may damage the unit and will invalidate the warranty Using your unit in wine cellars or in any room with a temperature under 61 F is not recommended The following advice and instructions should be followed closely IMPORTANT INSTRUCTIONS ENERGY SAVING TIPS TECHNICAL SPECIFICATIONS Cooling Capacity Power Input Coolant Moisture Re...

Page 6: ... Hose A 7 Drain Hose B 8 Exhaust Air Outlet Control Panel 1 Power ON OFF Button 2 Function Button 3 Timer Setting Button 4 A C Fan Speed Button 5 Sleep Function Button 1 2 3 4 5 6 7 8 6 LED Display 7 Alarm Indicator Light 8 Thermostat Temperature Setting Buttons 9 Air Conditioner Indicator Light 10 Dehumidifier Indicator Light 4 4 ...

Page 7: ...ensation must then be drained from Drain B 2 Drain B is located at the bottom of the rear of the unit and offers continuous drainage via gravity To use Drain B place a shallow pan underneath the drain outlet and remove the rubber cap In order to avoid spilling water while moving the unit from room to room please drain the condensation via Drain B before moving the unit In addition whenever you wil...

Page 8: ...the clips attached to Panel A to lock the panels into place The clips are to be placed on the L shaped edges of Panel A at the point where Panel A meets Panel B 4 Close the window up against the panels to secure them in the window frame 5 Twist the grey connector onto the exhaust hose and then pass Drain A through the exhaust hose before connecting the grey connector to the back of the unit you mu...

Page 9: ...ass Drain A through the exhaust hose before connecting the grey connector to the back of the unit you must do this whether or not you use Drain A 7 Twist the white connector onto the opposite end of the exhaust hose take Drain A and feed it through the wall window adapter then snap lock the white connector into the wall window panel adapter EXHUAST KIT INSTALLATION CONTINUED 1 DrainHose A 2 GreyHo...

Page 10: ...nce is fitted with a thermal protection device which allows the compressor to be started only after a time delay of up to three minutes CONTINUED ON NEXT PAGE Soft Touch Control Functions The air conditioner can now be plugged into a 120V 60Hz dedicated 15amp socket You are advised not to use an extension cord however if this is unaviodable the extension cord must be 14 gauge grounded at both ends...

Page 11: ...ess the FUNCTION button to select the dehumidification mode When the dehumidification mode is on the temperature buttons and the fan speed buttons do not function and the fan will operate on low speed The dehumidifier indicator light will illuminate and stay solid while the unit is dehumidifying When the humidity in the room is 50 or lower the compressor will not run the unit will not dehumidify a...

Page 12: ...amp sponge and dry it with a clean soft cloth Never use alcohol or any product containing solvents AIR FILTERS The air filters located on the back of the unit collect dust contained in the air To keep the dust from clogging the unit your unit must always be used with its air filters The build up of dust reduces the efficiency of the air conditioner Therefore the air filters must be cleaned every t...

Page 13: ... at least 1 away from walls and objects 3 Use screen instead of Flap vent for wall exhaust 4 Unit will overheat if the exhaust cannot fully vent 5 Push the power button to turn unit on The air conditioner dehumidifier LED indicator light blinks 1 In the A C function the ambient temperature has reached the set temperature and therefore the compressor has shut off 2 In the dehumidifier function the ...

Page 14: ... use of any power source other than that specified on the Product s specification label or repair by anyone other than a service facility specified by an authorized WINDCHASER representative 2 Diagnostic troubleshooting and travel costs 3 Operation and usage orientation costs 4 Performance or operation certification and testing costs 5 Normal wear and tear of parts including but not limited to hos...

Page 15: ...PONENTS ACCESSORIES AND ATTACHMENTS FURNISHED ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED WINDCHASER SHALL NOT BE LIABLE FOR THE LOSS OF USE OF THE PRODUCT ITS COMPONENTS ACCESSORIES AND ATTACHMENTS INCONVENIENCE LOSS OR ANY OTHER DAMAGES DIRECT OR CONSEQUENTIAL ARISING OUT OF THE USE OF OR INABILITY TO USE ...

Page 16: ... Fans Heaters Air Treatment Products and Portable and Mini Split Air Conditioners WindChaser Products Inc 4130 Del Rey Avenue Marina Del Rey CA 90292 Phone 310 827 8615 Toll Free 800 405 2943 Fax 310 827 8566 www windchaserproducts com ...

Reviews: