Dual Internal Ventilators
NOTE: Wiring harness #10220 is required to complete the installation
of dual VEN060I ventilators and must be ordered separately.
Cabinet Mounting
When using two (2) VEN060I ventilators the cabinet mounting must accommodate two discharge transitions. Wiring
and discharge holes are shown in FIG 6.
HINT:
Transition dimensions may very. Before assembling transitions to hood, fit them into the prepared cabinet
opening to be sure the openings are large enough to accommodate the transition. Enlarge the hole if required
Hood Preparation
The hood must be prepared for dual ventilat
discharge hole plates. To remove, break the metal webs holding the plate and remove completely. See FIG 5. Break the
metal webs by placing a screwdriver at one corner of the plate and hitting screwdriver sharply with a hammer. After breaking
a second web the plate can be flexed to break other webs
.
Wear eye protection when using tools.
Attach the transition (See DUCTING, pg 1), obtained separately from your local hardware or available through your dealer,
and install the hood as described previously in this instruction.
Ventilator Installation
Install the ventilators as previously described, see FIG 1 and instruction on same page of this document. Connect the
ventilators to the receptacle in the hood junction box using
Harness #10220,
ordered separately. Dress the wires and
5, using the wire tie supplied with the harness. Follow the remaining instructions for
operating checks to complete the installation.
FIG - 5
HOOD BACK
"A"
TIE
AIR DISCHARGE
HOOD TOP
KNOCKOUTS
KNOCKOUTS
AIR DISCHARGE