Wind Crest VEN100 Installation Instructions Download Page 4

 

 

1

2

3

4 4

3

2

1

POWER SUPPLY

N

RECEPTACLE 

BOX

RECEPTACLE

PLUG

G

L1

18 B #12

18 G #11

18 W #13

18 W #25
18 B #24
18 BL #23
18 R #22

1

8

 W

 #

2

0

1

8

 W

 #

1

0

1

2

 B

 #

1

1

8

 R

 #

4

1

8

 B

L

 #

3

1

8

 B

 #

2

1

8

 B

 #

1

7

1

8

 B

 #

1

6

1

8

 B

 #

1

8

1

8

 B

 #

1

9

HOOD

FOR HOODS WITH
HEAT LAMPS ONLY

HEAT LAMPS ONLY

FOR HOODS WITH

FIG6

1. REMOVE SHADED TWIST ONS

2. REMOVE WIRES AT RECEPTACLE

1

8

 B

 #

1

9

N

G

L1

1

8

 R

 #

4

1

8

 W

 #

2

0

12 W #13

1

8

 W

 #

1

0

1

2

 B

 #

1

18 G #11

12 B #12

1

8

 B

 #

2

1

8

 B

L

 #

3

1

8

 B

 #

1

8

1

8

 B

 #

1

7

1

8

 B

 #

1

6

4

4

2
3 3

2

1 1

WHI TE

BLACK

BLUE

RED

REMOTE BLOWER

JUNCTION BOX

CONDUIT

HEAT LAMPS ONLY

FOR HOODS WITH

HEAT LAMPS ONLY

FOR HOODS WITH

RECEPTACLE 

HOOD

BOX

POWER SUPPLY

CAPACITOR

YELLOW

YELLOW

MOTOR

GREEN

CHANGE #12 & #13 TO 12GA WIRE (SUPPLIED)

MODEL VEN140 ONLY

 

 
 

A.  Access the hood junction box, remove the designated twist on connectors, cut the four wires noted at the 

receptacle and remove the cut wires. 

B.  Access the remote blower wiring box by removing the top cover, set aside screws for later use. 
C.  Run four wires per local code, in conduit from remote blower to hood. 

NOTE:

 maintain white, black, blue and red color code from blower wiring box to hood connections. 

D.  Connect 4-wire from blower to hood with twist-on connectors from step   A; remote white to #13 (including 

other white wires in connection), remote black to #2 black, remote blue to #3 blue and remote red to #4 red. 

NOTE: 

When connecting the hood to power supply, replace the black #12 wire and white #13 wire on hood 

with the 12 ga wires supplied with the ventilator.See Fig   6. 
When remote blower is to be grounded to the Power Supply Main Ground use appropriate wire gage per local 
codes. See Fig   6. 
If the blower is grounded through the Hood the 18 ga Green Pigtail wire at the hood 

Must Be Changed to 12 

Ga, or Appropriate Wire Gage to Comply With Local Codes.

 

CAUTION:

 To prevent malfunction and/or harm to electrical components, connections are to be made per 

diagram and instructions. 

E.  Check rotation of blower wheel to be sure it rotates freely and does not rub brackets. 
F.  Replace blower top cover and screws from step   B. 
 
 
 
 

Summary of Contents for VEN100

Page 1: ...d between roof or wall and underside of flange with roofing mastic to prevent leaks For installation on a flat roof or roofs with pitch of less than 1 1 2 in 12 install ventilator on curb as shown in Fig 3 Position curb on sloping roof with 2 dimension facing down slope Position curb on flat roofs so that discharge screened end points away from prevailing wind 3 Connect the ventilator to exhaust s...

Page 2: ...EFT HAND INSIDE WALL OF THE HOOD OR ON THE HOOD CARTON LABEL IF THE SERIAL NUMBER OF THE HOOD DOES NOT COMPLY WITH THE ABOVE CONDITION THIS BLOWER CANNOT BE USED WITH THE HOOD REMOVE REMOVE REMOVE ATTENTION INSTALLER REMOVE SHIPPING BRACKET AND WOOD SUPPORTS BEFORE INSTALLING Roof Hood Outside Wall 10 Elbow 10 Duct 10 Transition FIG 1 10 Transition 10 Elbow Hood ROOF MOUNT OUTSIDE WALL MOUNT TYPIC...

Page 3: ...ew Down Slope of Roof or Wall 7 3 4 2 4 1 1 2 1 10 1 2 14 18 FIG 5 2 FIG 4 10 Adjustible Elbow Screw and Tape Joint 10 Diameter Duct Conduit 2 24 FIG 3 30 6 1 1 2 24 5 5 8 7 1 2 1 5 8 8 8 30 3 4 7 1 8 2 3 4 10 1 4 ...

Page 4: ...et aside screws for later use C Run four wires per local code in conduit from remote blower to hood NOTE maintain white black blue and red color code from blower wiring box to hood connections D Connect 4 wire from blower to hood with twist on connectors from step A remote white to 13 including other white wires in connection remote black to 2 black remote blue to 3 blue and remote red to 4 red NO...

Page 5: ...OOD WIND CREST ATTENTION INSTALLER BEFORE INSTALLING THIS BLOWER CONFIRM THAT SERIAL NUMBER ON HOOD TO USED IN THIS INSTALLATION IS GREATER THAN 102796 THE SERIAL NUMBER PLATE CAN BE FOUND ON THE LEFT HAND INSIDE WALL OF THE HOOD OR ON THE HOOD CARTON LABEL IF THE SERIAL NUMBER OF THE HOOD DOES NOT COMPLY WITH THE ABOVE CONDITION THIS BLOWER CANNOT BE USED WITH THIS HOOD ...

Reviews: