Wind Crest VEN100 Installation Instructions Download Page 1

 

By CNP INDUSTRIES, INC. 

P.O. Box 18645    Anaheim, Ca 92817   (877) 387-6721 

 

VENTILATOR VEN140/VEN100 INSTALLATION INSTRUCTIONS 

Ventilator Can Be Used For Roof or Wall Mounting 

Recommended for use over household gas and electric ranges and cooktops. READ ENTIRE INSTRUCTIONS 
BEFORE PROCEEDING. Installation must comply with all applicable codes. 

IMPORTANT:

 Save for local electrical inspector's use. 

INSTALLER:

 Please leave these instructions with this unit for the owner. 

OWNER:

 Please retain these instructions for future use. 

WARNING:

  BEFORE INSTALLING OR SERVICING THIS UNIT, SWITCH POWER OFF AT  

SERVICE PANEL AND LOCK SERVICE DISCONNECTING MEANS TO PREVENT POWER 
FROM BEING SWITCHED ON ACCIDENTALLY. IF PANEL CANNOT BE LOCKED, 
SECURELY FASTEN A WARNING TAG TO THE SERVICE PANEL. 

CAUTION: 

To reduce the risk of fire and to properly exhaust air, be sure to exhaust air outside. Do not exhaust air 

into spaces within walls or ceiling or into attics, crawl spaces or garages.

 

NOTE:

  THESE INSTRUCTIONS DESCRIBE THE INSTALLATION OF THE VEN140 OR VEN100 REMOTE 

HOOD, REFER TO THEIR SPECIFICATIONS FOR POWER REQUIREMENT COMPATABILITY.  

 

VEN140: 1-HP 3-SPEED MOTOR, 115V AC, 60Hz /

20 Amp CIRCUIT REQUIRED

 FOR WIND CREST 

VEN100: 

-HP 

3-SPEED MOTOR, 115V AC, 60Hz/

15 Amp CIRCUIT REQUIRED

 FOR WIND CREST 

 

1. 

Provide square hole through the roof or wall as shown by dash lines for conduit as shown in Fig-2. For reference, 
location of 10" duct connection and wiring connection is shown with solid lines. 

2. 

Install ventilator on roof or wall, with discharge (screened end) pointing down, according to STANDARD 
ROOFING PROCEDURES. 

Note:

 Front discharge edge should be on top of shingles and rear and side edges 

under shingles. Note: Unit must be sealed between roof or wall and underside of flange with roofing mastic 

to 

prevent leaks. For installation on a flat roof, or roofs with pitch of less than 1-1/2" in 12", install ventilator on 
curb as shown in Fig-3. Position curb on sloping roof with 2" dimension facing down slope. Position curb on flat 
roofs so that discharge (screened end) points away from prevailing wind. 

3. 

Connect the ventilator to exhaust system with a 10" diameter metal duct only. Use 10" adjustable elbow to adjust to roof 
angle. Tape and screw all joints to prevent air leaks. See Fig-4. 

4. 

Remove top cover of ventilator to access wiring connections. Retain mounting screws. 

5. 

Remove shipping bracket per separate instruction. 

6. 

Run electrical conduit per local code

 

to conduit outlet in bottom plate of ventilator (use liquid tight connection). Other 

end of conduit will connect to electrical box in your Wind Crest hood. See hood installation instructions for hood wiring 
location. 

7. 

Run four (4) 16 ga wires in conduit (1-black, 1-white, 1-blue and 1-red) between the ventilator and hood. 

Check for 

local code compliance. 

The ground wire should be 16 ga wire. See Fig-6 for wiring details. 

Check for local code 

compliance.

 

8. 

Dimensions of ventilator are shown in Fig-5. 

9. 

When connecting the hood to power supply

, replace the black-#12 wire and white-#13 wire on hood with the wires 

supplied with the remote blower.  
Power supply for the VEN140 plus hood requires a 120v, 20 amp, 60 Hz circuit, connected per local codes.   

10.  Rotate ventilator blower wheel to be sure it turns freely and does not rub on motor brackets. Check damper door to be 

sure it moves freely and spring returns door to closed position.  

11.  Check screen guard to be sure it is in position and secure. 

Check for removal of shipping bracket.

  

12.  Replace cover removed in Step-4 and secure with screws provided. All screws must be in place on cover. 

13. 

See Fig-1 for typical hood installations.

 

 

Summary of Contents for VEN100

Page 1: ...d between roof or wall and underside of flange with roofing mastic to prevent leaks For installation on a flat roof or roofs with pitch of less than 1 1 2 in 12 install ventilator on curb as shown in Fig 3 Position curb on sloping roof with 2 dimension facing down slope Position curb on flat roofs so that discharge screened end points away from prevailing wind 3 Connect the ventilator to exhaust s...

Page 2: ...EFT HAND INSIDE WALL OF THE HOOD OR ON THE HOOD CARTON LABEL IF THE SERIAL NUMBER OF THE HOOD DOES NOT COMPLY WITH THE ABOVE CONDITION THIS BLOWER CANNOT BE USED WITH THE HOOD REMOVE REMOVE REMOVE ATTENTION INSTALLER REMOVE SHIPPING BRACKET AND WOOD SUPPORTS BEFORE INSTALLING Roof Hood Outside Wall 10 Elbow 10 Duct 10 Transition FIG 1 10 Transition 10 Elbow Hood ROOF MOUNT OUTSIDE WALL MOUNT TYPIC...

Page 3: ...ew Down Slope of Roof or Wall 7 3 4 2 4 1 1 2 1 10 1 2 14 18 FIG 5 2 FIG 4 10 Adjustible Elbow Screw and Tape Joint 10 Diameter Duct Conduit 2 24 FIG 3 30 6 1 1 2 24 5 5 8 7 1 2 1 5 8 8 8 30 3 4 7 1 8 2 3 4 10 1 4 ...

Page 4: ...et aside screws for later use C Run four wires per local code in conduit from remote blower to hood NOTE maintain white black blue and red color code from blower wiring box to hood connections D Connect 4 wire from blower to hood with twist on connectors from step A remote white to 13 including other white wires in connection remote black to 2 black remote blue to 3 blue and remote red to 4 red NO...

Page 5: ...OOD WIND CREST ATTENTION INSTALLER BEFORE INSTALLING THIS BLOWER CONFIRM THAT SERIAL NUMBER ON HOOD TO USED IN THIS INSTALLATION IS GREATER THAN 102796 THE SERIAL NUMBER PLATE CAN BE FOUND ON THE LEFT HAND INSIDE WALL OF THE HOOD OR ON THE HOOD CARTON LABEL IF THE SERIAL NUMBER OF THE HOOD DOES NOT COMPLY WITH THE ABOVE CONDITION THIS BLOWER CANNOT BE USED WITH THIS HOOD ...

Reviews: