background image

System Connection

The system is connected via the RS232C (V.24) interface with a voltage
supply of +12V DC.

The following parameters are set as standard:

Transmission rate  9.600 Bit/s

Parity 

on

Parity 

odd

Parameters other than these standard values can also be selected. Wire
jumpers must be soldered onto the display circuitry in order to do so.

Wire jumper

IN/OUT

Parameter

JP1
JP2

OUT
OUT

9600 Bit/s

JP1
JP2

IN
OUT 

4800 Bit/s

JP1
JP2

OUT
IN 

2400 Bit/s

JP1

JP2

IN
IN 

1200 Bit/s

JP3

OUT

IN

Parity on

Parity off

JP4

OUT

IN

Parity odd

Parity even

JP5

IN
OUT

Self-test
Normal operation

The position of the wire jumpers on the display circuitry is illustrated in the
following diagram. The front plate can be removed by pressing both of the

 19

SYSTEM CONNECTION

Summary of Contents for BA66

Page 1: ...BA66 Cashier Display Product Manual Edition March 2003 ...

Page 2: ...hts including rights created by patent grant or registration of a utility model or de sign are reserved Delivery subject to availability technical modifications possible Pentium is a registered trademark of the Intel Corporation MS DOS Windows 95 Windows 98 Windows NT and Windows CE are registered trademarks of the Microsoft Corporation BEETLE is a registered trademark of Wincor Nixdorf Internatio...

Page 3: ...allation of the Connector 8 Tube based 8 Base Rotating Plate 10 Cashier Display Control 13 Control Sequences 14 Backspace without deleting 14 Line feed 14 Carriage return 15 Delete display 15 Position cursor 15 Delete to end of line 16 Set country code 16 Call display identification 18 System Connection 19 Cable Connection 21 Test Functions 22 Starting the test by entering a code 22 Technical Data...

Page 4: ...his equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Le présent appareil numéique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Commu...

Page 5: ...ed warranty engagement for 12 months beginning with the date of delivery This warranty engagement covers all those damages which occur despite a normal use of the product Damages because of n Improper or insufficient maintenance n Improper use of the product or unauthorized modifications of the product n Inadequate location or surroundings will not be covered by the warranty NOTES ON CARE 2 ...

Page 6: ... recovered thus saving energy and costly raw materials Please do not stick labels onto plastic case parts This would help us to re use components and material At this time there are still some parts that are not reusable Wincor Nlxdorf guarantees the environmentally safe disposal of these parts in a Recycling Center which is certified pursuant to ISO 9001 So don t simply throw your BA66 on the scr...

Page 7: ...try code are implemented Implementation of VFD technology ensures that the cashier display is ergonomically designed to achieve a high degree of readability irrespective of the cashier s angle of vision The display is connection to the point of sale system via a RS232C interface The voltage 12 V DC is also supplied via this interface The following two BA66 cashier displays are available to meet in...

Page 8: ...Cashier display with adapter for tube based installation Cashier display to TA61 or TA64 5 RECYCLING THE BA66 20 35 ...

Page 9: ...i de down remove key from the keyboard Important The cashier display must not be disconnected from the base by means of the release button X as the internal plug connection may otherwise become disconnected Pull the keyboard cable out through the metal opening see arrow INSTALLATION OF BA66 TO TA61 TA64 KEYBOARD 6 Keyboard cable X ...

Page 10: ...e cashier display to the rear side of the keyboard with the selftapping recessed head screws provided Then press the keyboard cable downwards and draw it through the metal opening into the cable run of the plastic base 7 TUBE BASED ...

Page 11: ...he Connector Tube based Press the release knob marked with the arrow in the drawing 1 and disconnect the hinge from the customer display 2 Thread the cable through the adapter 3 and then through the hinge 4 TUBE BASED 8 ...

Page 12: ...Connect the hinge and adapter Secure the connector cable in the strain relief The distance between the strain relief and the tip of the connector must be 66 mm 4 mm 9 TUBE BASED 66 mm 4 mm ...

Page 13: ... customer display and plug the adapter hinge into the customer display again until it locks into place Base Rotating Plate Press the release knob marked with the arrow in the drawing 1 and disconnect the hinge from the customer display 2 BASE ROTATING PLATE 10 ...

Page 14: ...Thread the cable through the base 3 and then through the hinge 4 Connect the base and the hinge 11 BASE ROTATING PLATE ...

Page 15: ...tomer display again until it locks into place A metal bracket of the strain relief is situated on the bottom side of the base Loosen one of the screws see arrow push the bracket aside and guide the connector cable from inward to outward under the bracket through the recess Tighten the screw BASE ROTATING PLATE 12 ...

Page 16: ...llowing functions are available n The cursor can be moved to the desired position n The cashier display can be deleted n The characters from the cursor to the end of the line can be deleted n An identification code can be requested n Country specific character sets can be selected n A self test can be performed 13 CASHIER DISPLAY CONTROL ...

Page 17: ... BS command hexadecimal 08 moves the cursor one space to the left If there is a character in the position to which the cursor moves it is not deleted This command is ignored if the cursor is already at the very start of the line Line feed The LF command hexadecimal 0A moves the invisible cursor down a line if it is positioned in one of the first three lines of the display The column position remai...

Page 18: ... 4A Position cursor The cursor position can be defined with this ESC sequence The cursor is not visible on the display whilst this is being carried out The following ESC sequence for example can be implemented Code Hexadezimal ESC Py Px H 1B 5B 31 3B 31 48 The parameters are transferred as ASCII characters and have the following meaning Parameter Meaning Py This parameter defines the line Px This ...

Page 19: ...ete to end of line This command deletes the characters from the cursor cursor position included to the end of the line The position of the cursor remains unchanged The ESC sequence is as follows Code Hexadezimal ESC 0 K 1B 5B 30 4B Set country code The following ESC sequence is implemented in order to select a countryspecific character set Code Hexadezimal ESC R n 1B 52 02 The hexadecimal value n ...

Page 20: ...ain 2 0C Latin America Furthermore PC code pages which contain additional country specific display codes can be selected by ESC R n with the following codes Country code Code page Character set Country 30 437 Standard Latin America 31 850 Latin 1 International Scandinavia Latin America 32 852 Latin 2 Hungary Poland Czechia Slowakia 17 CONTROL SEQUENCES ...

Page 21: ...display Call display identification The identification is called with the following ESC sequence ESC 1 1 H The following is displayed on the screen when the sequence is entered Code Hexadezimal ESC Py Px H 1B 5B 31 3B 31 48 Pn1 Type of display 2 VFD display Pn2 PROM version currently 00 depends on approved PROM version Pn3 Character set 2 modif IBM character set Pn4 Number of lines 4 Pn5 Column li...

Page 22: ...ers must be soldered onto the display circuitry in order to do so Wire jumper IN OUT Parameter JP1 JP2 OUT OUT 9600 Bit s JP1 JP2 IN OUT 4800 Bit s JP1 JP2 OUT IN 2400 Bit s JP1 JP2 IN IN 1200 Bit s JP3 OUT IN Parity on Parity off JP4 OUT IN Parity odd Parity even JP5 IN OUT Self test Normal operation The position of the wire jumpers on the display circuitry is illustrated in the following diagram...

Page 23: ...erior housing clips underneath the plate The wire jumpers are then accessible Cashier display circuitry SYSTEM CONNECTION 20 Wire jumpers Fluorescent display glass front Print RS232C socket Rear side Print ...

Page 24: ...ther which is connected to the COM interface of the point of sale system Similarly the voltage 12V is also supplied to the display via the COM interface The pins of the 6 pin mini DIN socket and the 9 pin D sub socket are assigned as follows 6 pin mini DIN Socket Signal 9 pin D Sub Socket 1 RTS 7 2 CTS 8 3 GND 5 4 RXD 2 5 TXD 3 6 12V 1 4 9 6 21 CABLE CONNECTION ...

Page 25: ...isplay Code ESC 2 nn 2 2 20c The current version number 00 99 will be indicated in place of nn The test software performs the following functions n The microprocessor and the RAM within the processor are tested Errors detected are displayed n Formation and comparison of the PROM checksum Errors detected are displayed n The display type and version number of the microprogram are displayed n The par...

Page 26: ...ossible via software control using ESC sequences and JP5 wire jumper Interface RSC232C asynchronous full duplex operation Transmission modes standard 9600 bit s parity on parity odd even uneven parity optional with 9 6 4 8 2 4 1 2 kbit s adjustable via wire jumpers Voltage supply 12V 10 with max 500mA typ 350mA inrush current max 600 mA System connection RS232C V 24 with 12V DC voltage supply Dime...

Reviews: