12
OPM-139/E
2. If the generator set is connected to an existing
distribution system, a fully isolated manual transfer switch
must be installed. The transfer switch prevents damage to
the generator and the other circuit components if main
line power is restored while the generator is connected.
Installing a transfer switch also permits the use of normal
fusing.
3.Many homes and construction sites are wired for at least
60 to 100 Amp entrance service, much greater than the
capacity of this portable generator. When installing
the generator at these sites, a secondary emergency
distribution panel may have to be installed. The
emergency distribution panel must be installed by a
licensed electrician according to all applicable codes.
The electrician will move the critical circuits to be
powered during the outage to the emergency panel.
Keep in mind only a limited amount of amperage is
available from the generator set. Some circuit breakers
may still have to be turned off to prevent an overload on
the generator during the initial start up. See the
nameplate on your generator for the amperage
capabilities of your unit.
CAUTION: EQUIPMENT DAMAGE
Failure to properly limit and balance the load applied to
the generator will cause the generator to produce low
voltage and may damage the engine generator set. It may
also cause severe damage to the loads connected to the
generator at that time. Improper loading of the generator
set constitutes abuse and will not be covered by warranty.