SPECIFICATIONS

GEAR LUBE

 

Volume 

    0.875 

Pint

 

Type 

     SAE 

80-90W-140

W70PTO

  

Continuous 

Watts 

  69,000

Volts      120/240

Phase 

     Single 

 

Amps 

     287 

Power 

Factor    1.0

Input 

Speed 

    540 

RPM

Generator Speed 

 

 

1800 RPM

Input Shaft   

 

 

 

1 3/4” - 20 Spline

Required Tractor PTO HP  

138

W70PTOS

  

Continuous 

Watts 

  69,000

Volts      120/240

Phase 

     Single 

 

Amps 

     287 

Power 

Factor    1.0

Input 

Speed 

    1000 

RPM

Generator Speed 

 

 

1800 RPM

Input Shaft   

 

 

 

1 3/4” - 20 Spline

Required Tractor PTO HP  

138

Summary of Contents for W70PTO

Page 1: ...should ever need to contact us concerning this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER ____________________________...

Page 2: ...should be followed during installation and maintenance of the generator Read and understand all instructions in the manual before starting and operating the generator Keep this manual available for f...

Page 3: ...ONS This engine generator set has been designed and manufactured to allow safe reliable performance Poor maintenance improper or careless use can result in potentially deadly hazards from electrical s...

Page 4: ...se Single Amps 287 Power Factor 1 0 Input Speed 540 RPM Generator Speed 1800 RPM Input Shaft 1 3 4 20 Spline Required Tractor PTO HP 138 W70PTOS Continuous Watts 69 000 Volts 120 240 Phase Single Amps...

Page 5: ...rator causing overheating and equipment damage Observe input RPM specifications The generator may be foundation mounted for use as standby power source or trailer mounted and used as portable electric...

Page 6: ...t or nearly straight line between the power take off and the generator input shaft Misalignment must be less than 15 degrees during generator operation even though the mechanical design of the tumblin...

Page 7: ...only has to be sized to the amperage of the circuit breaker in the main distribution panel that is feeding it Before deciding which system to install first determine which loads you can safely run on...

Page 8: ...ervice hook up make sure load to be transferred to standby generator will not exceed generator rating Watthour Meter Watthour Meter To Power Line Master Switch To Power Line Master Switch Distribution...

Page 9: ...ning how much load can be applied to the generator and how it should be distributed among the generator output receptacles the following formulas may be useful Get load voltages current and wattage fr...

Page 10: ...d slowly increase engine speed until the output reaches approximately 240 to 245 volts in green portion of voltmeter scale 5 Plug 4 wire load cord set into receptacle Place transfer switch in the emer...

Page 11: ...d or short circuit must be reset by moving to off before re closing 7 With engine and generator running smoothly switch on the electrical load while watching the frequency meter Adjust engine throttle...

Page 12: ...ons or in severe weather such as rain or blowing snow LUBRICATION The generator bearings are factory lubricated and sealed and require no further lubrication The splined generator input shaft should b...

Page 13: ...l box Inspect all wiring for correct routing fraying insulation and secure connections 2 Remove end cover Vacuum or blow dust and debris from the inside of the generator Inspect wiring for loose conne...

Page 14: ...ary 2 Reduce load if it is higher than the rated capacity of the generator see generator nameplate 3 Generator requires 2 HP 1000 watt output Obtain larger engine if necessary 4 Repair adjust or repla...

Page 15: ...15 OPM 142 D WIRING DIAGRAM BACK VIEW 0 1 2 0 34 5 6 37 8 6 9 6 9 9...

Page 16: ...you may have other rights which vary from state to state Note Some states do not allow limitation on the duration of implied warranty and some states do not allow the exclusion or limitation of incid...

Reviews: