Winco ECV2510-3 Owner'S Manual Download Page 13

Page 11

60706-130

7150-01

REF

DESCRIPTION

QTY

PART NBR.

001

Cap Screw 5/16”-18x2 3/4

4

51101-000

002

Lockwasher 5/16”

4

480-000

003

Lockwasher Split Type ¼”

3

479-000

004

Machine Screw

3

45633-000

005

Lockwasher 11/16 Int.

1

40552-000

006

Flat Washer

1

21867-000

007

Lockwasher

1

20039-000

008

Hex Nut 1/2-20

1

9549-000

009

Lockwasher

2

636-000

010

Cap Screw 1/2-13 x 1

1

48178-000

011

Machine Screw

4

44342-000

012

Lockwasher

5

6376 -000

013

Hex Nut 8-32

5

5113-000

014

Machine Screw

28

40746-000

015

Cap Screw 7/16-20 x1 3/4

7

43781-000

016

Cap Screw 7/16 -20 x 1 1/2

1

54806-000

400

Generator

1

61367-002

401

Fan Assembly

1

23404-000

411

End Bracket

1

51046-003

412

Oil Seal

1

46912-000

413

Bearing

1

46913-000

414

Retainer Plate

1

44318-000

415

Gasket

1

20136-000

416

Spacer

1

20137-000

417

Pinion Gear

1

46545-000

418

Key

1

20159-000

419

Lockwasher

1

20139-000

REF

DESCRIPTION

QTY

PART NBR.

420

Hex Nut

1

20160-000

430

Armature Assembly

1

64794-000

431

Armature

1

64794-001

432

Bearing

1

50215-000

440

Field Shell & Coil Assembly

1

61368-002

441A Field Coil

1

64787-000

441 B Field Coil

1

  64787-001

442

Pole Shoe

2

43473-000

443

Pole Shoe Retainer

2

43474-000

444

Field Shell

1

61153-001

447

AC Brush

12

24981-000

448

Lead Shield

1

23478-000

449

Brush “Q”

2

53949-000

460T

Brush Rack Assembly

1

53977-000

460B Brush Rack Assembly

1

53977-001

462

Brush Holder

12

23500-002

463

Condenser

3

41221-000

467

Rectifier

1

91452-000

468

Ground Strap

1

41387-007

469

Spacer

14

23532-000

470

Brush Holder Spacer

2

52559-000

471

Mounting Plate

6

53975-000

472

Brush Holder “Q”

2

23500-000

491

End Cover

1

55438-023

610

Base

1

51147-000

N/I

Wiring Harness

1

64543-000

GENERATOR REPLACEMENT PARTS LIST

N/I  -  Not Illustrated

TECHNICAL DATA

Generator Specifications:

kW - 20;  Volts -120/240;  Amps - 83;  PH - 1;  Hz -60;
Input - 1000/1182 RPM;  Generator - 3600 RPM

Resistances:

Field Coils (rectifier circuit) 17.1 - 18.8 Ohms; Excitor Volts - 92, Amps 2.4
Field Coils (regulator circuit) 11.2 - 12.6 Ohms; Excitor Volts - 55, Amps 2.8 (full load)
Armature  (Q Winding) .080 - .088 Ohms, (G1 to N & G3 to N) .025 - .0275 Ohms

Summary of Contents for ECV2510-3

Page 1: ...TION AND OPERATION INSTRUCTIONS SAFETY FIRST READ THIS MANUAL BEFORE OPERATING YOUR GENERATOR ECV2510 3 ECV2512 3 Note Unit shown is the ECV2512 the only dimension that changes on the ECV2510 is the l...

Page 2: ...n 3 Pre Wire Checklist 4 Initial Start 4 ELECTRICALCONNECTIONS 4 FINALSYSTEMCHECK 5 MAINTENANCE General Information 5 Periodical Maintenance 5 Generator Maintenance 5 Lubrication 7 TROUBLESHOOTINGTABL...

Page 3: ...hazard of possible explosion and or fire a Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate 3 DEADLY EXHAUST GAS Exhaust fumes from any eng...

Page 4: ...eye on the top of the generator When loss or damage is noted after delivery segregate the damaged material and contact the carrier for claim procedures Concealed damage means damage to the contents of...

Page 5: ...5 Heat and Cold All generators radiate considerable heat when they are running In addition these units are generally mounted in a somewhat restricted location which precludes natural cooling Allow sp...

Page 6: ...ge regulator The regulator may not effect the no load voltage to any degree Notice If for any reason during the check out procedure the voltage and frequency are not correct stop the engine and refer...

Page 7: ...recommended that the generator be operated at least monthly under normal loads to familiarize operators with the procedures and controls as well as to dry out any accumu lated condensation or other m...

Page 8: ...the meter If meter indicates continuity any reading lower than one meg ohm the armature is grounded Dirt between the slip rings and on the insulator surface can cause ground ing If grounding was indic...

Page 9: ...ts have not located the trouble remove the armature and have it tested for opens shorts and grounds on a growler 4 Lubrication The generator bearings are factory lubricated and sealed and require no f...

Page 10: ...t AC voltage to rectifier Check rectifier output DC voltage to positive DC brush If no DC voltage is present at the brush replace the rectifier Check for dirty slip rings Clean them if they are dirty...

Page 11: ...TY PART NBR 001 VoltageRegulator 1 98884 002 002 MountingBracket 1 64790 000 003 Grommet 1 9336 000 004 MachineScrew 2 16165 000 005 Lockwasher 2 484 000 006 FlatWasher 2 598 000 007 HexNut 2 6372 000...

Page 12: ...Page 10 60706 130 7150 01 GENERATOR ILLUSTRATION...

Page 13: ...e Assembly 1 64794 000 431 Armature 1 64794 001 432 Bearing 1 50215 000 440 Field Shell Coil Assembly 1 61368 002 441A Field Coil 1 64787 000 441 B Field Coil 1 64787 001 442 Pole Shoe 2 43473 000 443...

Page 14: ...00 142 Gear input Drive 1 44832 000 46546 000 144 Gasket Cover 1 20016 000 20016 000 146 Backing Plate N A N A 147 Safety Shield N A N A 148 Gear Driven 1 46546 000 N A 149 Bearing 2 54665 000 N A 150...

Page 15: ...Page 13 60706 130 7150 01...

Page 16: ...dwarranty andsomestatesdonotallow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may notapplytoyou Thiswarranty givesyouspecificlegalrights yo...