Winco EC6010DR/R Installation, Operation And Maintenance Instructions Download Page 4

Page 2

60706--176

SPECIFICATIONS

MODEL

EC6010DR/R

Generator
Surge Watts

6000

Continuous Watts

5500

Volts

120/240

AMPs @ 240 Volts

22.9

Output 4 Wire Re-connectable - 120 or 120/240V

Engine
Size

9.9 HP

Model

Hatz U-4 Var XI

 Type -

See Engine Shroud For Type

Fuel Capacity- N/A - External, Customer Supplied Tank
Fuel Consumption

.7 gal/hr

Starting  System

12 Volt Electric

Key - Local/Remote

Muffler

Low Tone

 Type -

1B40

Stop System

Key - Local/Remote

Complete Unit
Weight (dry)

245  LBS

Dimensions  LxWxH

26.3 X 18.125 X 21.7

Owner Must Provide
Fuel

#2  Diesel

Oil Type

5W-40 CD, CE, CF, CG

See engine manual for  additional oil information.
Oil Capacity

1.64 Quarts

INTENDED USES

1. These engine generator sets have been designed
specifically for Vehicle mounting and mobile use. The
generator output is available in the junction box on the top
of the generator shell. Receptacles are not provided in the
“control box” since the unit is intended to be wired into the
vehicles electrical distribution system. The vehicle
electrical distribution system must include a main line
circuit breaker (MLCB) to protect the generator and your
wiring. The vehicle distribution wiring and receptacles
carry the generator output power to the loads (portable
lights appliances and tools). These units are dual wound
generators, with two separate 120 Volt windings. These
windings can be connected for full power 120 volt OR 120/
240 volt output. When connected for 120/240 dual voltage,
the 120 volt loads must be split and balanced to avoid
overloading one of the generator 120 volt windings. See
unit capabilities for further explanation.

2. These units require large quantities of fresh air for
cooling of both the engine and the generator. Fresh air is
drawn from both the engine end and the generator end
and is exhausted at the center of the unit. For safety, long
life and adequate performance, these units should not be
run in small compartments without the access door open
to allow positive fresh air flow.

RESTRICTED USES

1. DO NOT remove from the base assembly. Removal of
the generator from the base assembly or operating
without the shock mounts installed may cause excessive
vibration and damage to the engine generator set.

2. DO NOT operate this generator without the
compartment door open., i.e. generator compartment of
rescue vehicles, motor homes or travel trailers. Closed
compartments will not allow enough free flow fresh air to
reach the engine generator set for cooling. Overheating
will cause damage to both the engine and the generator.
Small compartments may also develop hot spots where
there is very little air flow and could cause fire.

3. DO NOT attempt to operate this unit at 50 cycles. These
units are designed and governed to operate at 60 Cycles
only.

UNIT CAPABILITIES

Generator Connections - The diagram below represents
a typical 5500 watt generator.  Receptacles A and B are
the two 120 Volt duplex receptacles. Up to 2750 watts at
120 volts (22.9 Amps) can be taken from the generator at
each of the receptacles. This generator produces 120
and 240 volt, 60 Hz (Hertz), AC (Alternating Current).

CAUTION: EQUIPMENT DAMAGE

CAUTION MUST BE EXERCISED TO PREVENT
OVERLOADING EITHER OF THE GENERATORS
120  VOLT OUTPUT CIRCUITS (A OR B).

Check the appliance or tool nameplates for the current
and voltage to insure compatibility.  Remember that
power taken from receptacle C reduces the power
available at both A and B.  Any remaining 120 volt loads
should be equally divided between A and B.  Failure to
split the load will cause permanent damage to the stator.
Although circuit breakers are provided, damage due to
overloading constitutes abuse and will not be warranted.

Summary of Contents for EC6010DR/R

Page 1: ...60706 176 OWNERS MANUAL INSTALLATION OPERATION and MAINTENANCEINSTRUCTIONS EC6010DR R EMERGENCY RESCUE SERIES...

Page 2: ...5 Operating Speed 5 Connecting The Load 6 Wiring 6 Engine Care 7 Low Oil Level Shutdown System 7 Generator Care 7 Cleaning 8 Things To Check BEFORE You Call For Service 8 Outline Drawing 9 Engine Gene...

Page 3: ...ended for permanent instal lation Consult dealer for units intended for stand by service Installing a generator set is not a do it yourself project Consult a qualified licensed electrician or con trac...

Page 4: ...from both the engine end and the generator end and is exhausted at the center of the unit For safety long life and adequate performance these units should not be run in small compartments without the...

Page 5: ...GENERATOR SET UNDER THESE CONDITIONS MAY RESULT IN DAMAGING THE GENERATOR STATOR AS WELL AS THE MOTOR WINDING Because the heavy surge of current required for starting motors is required for only an in...

Page 6: ...ormance These generator sets must be started and operated with a twelve 12 volt battery The 12 volt battery must be rated at 235 CCA or larger For units mounted in vehicles it is recommended that you...

Page 7: ...p at this point to indicate the unit is operating properly d To shut the unit off rotate the key switch to the O position and the unit is stopped by shutting off the fuel solenoid STARTING HINTS 1 Col...

Page 8: ...ate rating Overloading may cause damage to the generator and or the loads b Most electric tools and devices will have the voltage and amperage requirements on their individual nameplates When in doubt...

Page 9: ...l with the engine warm b Replace oil drain plug c Remove oil filler plug and refill with new oil Refer to the table in the engine manual for the proper grade of oil based on your operating temperature...

Page 10: ...ler area to remove all grass dirt and combustible debris to prevent a fire 3 On engine mufflers equipped with spark arresters the spark arrester must be removed every 50 hours for cleaning and inspect...

Page 11: ...Page 9 60706 176 UNIT LAYOUT...

Page 12: ...49 000 4 5 16 18 Flangenut 13 98807 000 4 Shockmount 14 91658 007 4 3 8 16 X 2 5 HHCS 15 16250 000 4 3 8 16 Flangenut 16 98806 000 4 Safety Washer REF PART NBR QTY DESCRIPTION 17 15084 003 1 Generator...

Page 13: ...EL SYSTEM GENERATOR ASSEMBLY REF PART NBR QTY DESCRIPTION 1 15013 000 4 10 32 X 3 5 Screw 2 21975 000 4 10 Lockwasher 3 15192 000 4 20 Hex Nut 4 479 000 4 Lockwasher 5 15857 000 1 Stator Complete 6 15...

Page 14: ...Page 12 60706 176 DC WIRING CONNECTIONS...

Page 15: ...Page 13 60706 176 AC WIRING CONNECTIONS...

Page 16: ...to 12 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warranty and some states do...

Reviews: