![WimTec SanTec Ocean U8 Installation And Operating Instructions Manual Download Page 15](http://html.mh-extra.com/html/wimtec/santec-ocean-u8/santec-ocean-u8_installation-and-operating-instructions-manual_984324015.webp)
Urinal control
SanTec OCEAN U8
15
EN
OCEAN U8
Start of operation
1.
Screw on electronic module.
2.
Adjust flushing time
if necessary. Save water! Adjust flushing time according to flow
pressure and flushing quantity. (1 – 15 s adjustable / 5 s pre-adjusted)
3.
As function control after start of operation the red Led is shining for 1 min at
user recognition.
4.
Mount front plate – make function test.
5. Adjust active range
if necessary (30 – 70 cm adjustable / 50 cm pre-adjusted)
6.
Fix front plate.
7.
SanTec OCEAN U8 is ready for operation.
Function
Minimum stay time:
4 s
Intelligent pre-flushing:
1 s, if urinal was not used for
more than 5 min
Adjustable main flushing:
from 1 – 15 s
Hygiene flushing:
at 24 h non-use