14 Washbasin fitting
SanTec LOFT
EN
LOFT
Configuring the functions
12
34
56
ON
OF
F
1
4
2
3
1
Interval control
2
Time control
3
Status LED
4
DIP switches
Function activation – DIP switch 1–6:
DIP switch
Function
Factory setting
Description
1
Range
ON
Page 17
2
Cleaning stop
OFF
Page 17
3
Continuous flow
OFF
Page 18
4
Stagnation rinse
OFF
Page 19
5
Stagnation rinse time
OFF
Page 19
6
Shut-off delay
OFF
Page 20
Regulator controls:
1. Interval control
for stagna-
tion rinse, default setting 24 h
(setting range 3–48 h).
2. Time control
for wa-
ter arrest, default setting
1 min (setting range 30 s to
10 min).
3. Status LED
indicates low
battery charge by flashing
every 2 s (battery version
only).
4. DIP switches:
Rule applies to all controls:
Move counterclockwise to decrease the setting.
Move clockwise to increase the setting.
!