Urinal control
SanTec OCEAN U8
17
EN
PROOF U8
Start of operation (mains supply)
1.
Screw on electronic module.
2.
Open shut-off valve.
3.
Switch on power supply, led on power supply is shining.
4.
Adjust flushing time
if necessary. Save water! Adjust flushing time according to
flow pressure and flushing quantity.
(1 – 15 s adjustable / 5 s pre-adjusted)
5.
As function control after start of operation the red led is shining
for 1 min at user recognition.
6.
Mount front plate – make function test.
7/8. Adjust active rang
e if necessary (30 – 70 cm adjustable / 50 cm pre-adjusted)
9.
Fix front plate.
Function
Minimum stay time:
4 s
IIntelligent pre-fl ushing:
1 s, if urinal was not used for
more than 5 min
Adjustable main fl ushing:
from 1 – 15 s
Hygiene fl ushing:
at 24 h non-use
Stadium mode:
When used more than 5 times within 3
minutes the control changes to stadium
mode: After the 6th use only one fl ushing
per minute is released.