background image

 

A: DRAIN OUTLET         B: UV SAND FILER         C: POOL    
D: WATER PUMPS         E: SKIMMER

Suction is taken from the skimmer at the pool surface to the water pump 
on the bottom of the pool. Due to gravity, precipitate heavier impurities. 
Later the water will circulated downwards to bio-cells. So the nitrifying 
bacteria produced by bio-cells will resolve NH3 and NH2 to non-poisonous. 
Finally, the water is circulated downwards through UV-C clarify. So the al-
gae, bacteria and microorganisms will be killed. After filtration, the water 
will be returned to the pool via outlet.
CAUTION:the filter material need to be washed at intervals to remove the 
particles. Or use its retained backwash system if the pressure exceeds 
0.3bar.

INSTALLATION

INSTALL FILTER

1> Place the filter on a horizontal and clean place.
2> Place the filter in its final location
3> Install the connections, inlet, outlet, drain (1 ½ inches hose)
4> Install the pressure gauge by handwork. Do not use tool to tighten.

INSTALL FILTER MATERIAL

In order to obtain maximum efficiency from your filter, it should be filled 
with 30% filter materials.
1> Connecting pipe after position
2> Open the filter cover
3> Fill the filter with water to half capacity.
4> Pour the required quantity of filter materials inside.
  (

CAUTION

: not drop any inside the inner pipe.)

5> Clean the sealing at the joint part.
6> Fix the filter cover in place

CAUTION

1> the filter should be installed as close as possible to the pool and best in
the water 0.5meters below,
2> Make sure there is drainage available at the place where the filter is to 
be installed.
3> Always leave enough space around the filter in order to perform the 
necessary. Examinations and maintenance during the filter’s life.

FILTRATION PROCESS

This selector valve has a handle of 5 positions that selects any of the nec-
essary operations to obtain the maximum efficiency from the filter.

CAUTION

: Please always switch off the pump when changing the position 

of the selector valve.

FILTER

When the pump switched off, place the handle of the selector valve in the 
“filtration” position, switch on the pump. During the operation, it is advis-
able to observe the pressure gauge from time to time as the indicated the 

© by WilTec Wildanger Technik GmbH 

Seite 13 

http://www.wiltec.de
http://www.aoyue.eu
http://www.teichtip.de

Version 07.2015

Summary of Contents for CSF-500

Page 1: ...reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us by WilTec Wildanger Technik GmbH Seite 10 http www wiltec de http www aoyue eu http www teichtip de Version 07 2015 ...

Page 2: ...ge that our clients take some basic safety precautions when using this device Please read the operation instructions carefully and make sure you have understood its content Always use a grounded power connection with the appropriate mains voltage You can find the corresponding mains voltage on the type plate If you have any doubts about the connection being grounded have it checked by a qualified ...

Page 3: ...ke sure no children or adult sit on this filter 4 do not connect this filter to any taps The high pressure from the taps exceeds the maximum allowable working pressure 5 do not use solvents for cleaning the filter this could damage the filter especially its finish CAUTION PLEASE KEEP THIS MANUAL HANDY FOR FUTURE USE OPEN THE PACKAGE 1 Please carefully check the accessories and products when open t...

Page 4: ...lled with 30 filter materials 1 Connecting pipe after position 2 Open the filter cover 3 Fill the filter with water to half capacity 4 Pour the required quantity of filter materials inside CAUTION not drop any inside the inner pipe 5 Clean the sealing at the joint part 6 Fix the filter cover in place CAUTION 1 the filter should be installed as close as possible to the pool and best in the water 0 ...

Page 5: ...tallation in the FILTRATION position The water flowing into the pool will be cloudy from a few seconds So to prevent it from reaching the pool there is RINSE position from the selector valve which is operated as following immediately after the BACKWASH put the valve in the RINSE position and switch on the pump fro 1 minute after which the pump is switched off and the valve placed in the FILTRATION...

Page 6: ...vity 4 When you need to start up the filter again after a period of inactivity follow the instructions stated in the paragraph START UP DRAWING No name No name No name 1 cover 6 packet ring 11 UVC device head 2 screw 7 quartz tube 12 filter tank 3 gasket 8 o ring 1 13 rubber gasket 4 shim 9 o ring 2 14 sealing nut 5 nut 10 UVC lamp 36W 15 bio cell by WilTec Wildanger Technik GmbH Seite 15 http www...

Page 7: ... points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consum...

Reviews: