Detailed error descriptions and solutions

 

 
Residual water in the shower tray 
 

In order for the lifting unit to switch on cleanly when discharging waste water, the incoming waste water 
pipe should have a gradient of at least 2

–3 % and a height difference of at least 20 cm from the siphon 

to the inlet to the lifting unit. 
 
This is both necessary for the pressure switch in the toilet lift to work properly, turn on the lift and pump 
out the water. Possible faults, if this is not taken into account, are that the lifting unit does not pump the 
water out or that there is always too much left in the pipes or possibly in the shower tray. 

 
Loud noises, motor does not start or starts heavily, water is not pumped out. 
 

These symptoms occur when the lifting system is blocked. 

 

If the system is clogged with toilet paper and faeces, in most cases it is sufficient to carefully flush the 
system backwards with water. To do this, simply apply a little water pressure to the outlet of the lifting 
unit, e.g., with a garden hose, so that the residues from the pump body are flushed back into the lifting 
unit. Please make sure that there is no water pressure on the collecting tank of the lifting unit. Otherwise, 
the  pressure  switch  of  the  lifting  unit  will  be  damaged  and  the  automatic  on/off  switch  will  no  longer 
function correctly. 
 
In the case of heavy blockages/blockages caused by solids which have jammed in the pump body, it 
may be necessary to open the pump so that the solids can be removed. 
 
Strong impacts from the solids in the lifting unit may even damage the motor bearings. In this case, the 
motor of the lifting unit must be opened and the bearing replaced. This fault usually manifests itself after 
the removal or rinsing out of larger solids. The lifting unit can then still be turned freely by hand, but as 
soon as you try to start the engine, it blocks and only hums. 
 
Cleaning can easily be done through the maintenance opening on the top of the lifting unit. 

 
Lifting unit does not pump down and is in continuous operation 
 

This error occurs in lifting systems that were switched off (no power) and still had inlet, or where sewage 
was discharged under pressure from a dishwasher or washing machine, or that had more inlet than the 
pump could pum

p out. As a result, the systems were “overfilled.” 

 
It can then happen that water gets into the pressure switch of the lifting unit. This disturbs the function 
of the pressure switch. The system then either runs continuously or no longer switches on automatically. 

 
 
Cleaning the unit

 

 
The  lifting  unit  may  only  be  cleaned  from  the  outside  with  mild  detergents,  a  damp  cloth  and  soapy 
water. Damage caused by incorrect cleaning agents is not covered by the warranty. 
 

 

Summary of Contents for 62138

Page 1: ...perating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insign...

Page 2: ...ervice wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Ou...

Page 3: ...rience and or knowledge unless they are supervised or instructed by a person responsible for their safety how to use this device Children should be supervised to ensure that they do not play with the...

Page 4: ...eu 06 2021 1 http www teichtip de Safety instructions CAUTION On standing waters garden and swimming ponds and in their surroundings the device may only be used with a residual current circuit breaker...

Page 5: ...drinking water circuit The pumping of aggressive liquids and abrasive materials must be avoided in any case The pump must be protected from frost The pump must be protected against dry running The uni...

Page 6: ...cording to the EU standard the centre of the horizontal outlet must be 18 cm above the floor shell 18 cm above FFB Important PRESSURE LESS When connecting a washing machine to the lifting unit the was...

Page 7: ...agram The non return valve included in the packaging must be installed The standard EN 12050 3 EN 12050 4 stipulates that if a WC is connected only a shower a bidet and a washbasin can be connected to...

Page 8: ...s on the top side of the appliance and the other consumers in the bathroom or kitchen are the thin sides of the appliance The connected appliances should be operated separately and not continuously e...

Page 9: ...on piece the pipe should have a diameter of 40 or 32 mm Seal the connection with the clamp Checking the assembly of the check valve If the waste water is to be pumped upwards install the check valve a...

Page 10: ...the pipes there is residual water in the shower tray Maintenance and cleaning Read the safety instructions and instructions carefully before opening the unit for maintenance Maintenance should only b...

Page 11: ...e pump impeller for blockage when the mains plug is unplugged The non return valve has been mounted the wrong way round Mount the non return valve in the correct direction is launched in unintended ma...

Page 12: ...herwise the pressure switch of the lifting unit will be damaged and the automatic on off switch will no longer function correctly In the case of heavy blockages blockages caused by solids which have j...

Page 13: ...er European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste bu...

Reviews: