© by WilTec Wildanger Technik GmbH
Item 52016
Page 6
10 2021
-1
Basic functions
1. Press
“SET”
(5)
and
“+”
(6)
while the incubator is not supplied with energy to restore the factory
settings (turning interval: every 2 h during 10 s).
2. Press the LED switch
(2)
during 3 s to test the egg turning function. By pressing the up and
down buttons
(6, 7),
the turning interval can be adjusted.
Temperature adjustment
The factory temperature setting is 38
℃
(100 °F). The temperature can be adapted to different types of
clutches and ambient temperature. Should the incubator not have reached 38
℃
(100 °F) even after
several hours of operation, check the following:
1. Has the temperature been set to 38
℃
(100 °F)?
2. Does the fan work properly?
3. Is the lid closed?
4. Is the ambient temperature above 18
℃
(64.4 °F)?
To check and modify the temperature settings, proceed as follows:
1. Press the
“SET” button
(5)
once.
2. Press
“+”
(6)
or
“–”
(7)
to adjust the desired temperature.
3. Press
“SET”
(5)
to complete the adjustment.
Adjustments of temperature alarm value (AL and AH)
The alarm value is set to 1
℃
(33.8 °F) in the factory.
Adjustment of alarm when temperature is too low (AL)
1. Press the
“SET” button
(5)
during 3 s.
2. Press the
“SET” button
(5)
repeatedly until
“AL” is displayed.
3. Press
“+”
(6)
or
“–”
(7)
to define the desired temperature alarm value.
Adjustment of alarm when temperature is too high (AH)
1. Press the
“SET” button
(5)
during 3 s.
2. Press the
“SET” button
(5)
repeatedly until
“AH” is displayed.
3. Press
“+”
(6)
or
“–”
(7)
to define the desired temperature alarm value.
Adjustment of upper and lower temperature limit (HS and LS)
With the upper limit set to for example 38.2
℃
(100.8 °F) and the lower limit to 37.4
℃
(99.3 °F), the
temperature of the incubator can only be adjusted to a value comprised between these two limits.
Calibrating the temperature sensor
The thermometer is set to 0
℃
(32 °F) in the factory. In case the temperature display has deviating
values, you can adjust the temperature sensor. Use a standardised external thermometer to determine
the correct temperature values. The deviation between the temperature display and the external ther-
mometer is the value to be set.
1. Press the
“SET” button
(5)
during 3 s.
2. Press the
“SET” button
(5)
repeatedly until
“CAU” is displayed.
3. Press
“+”
(6)
or
“–”
(7)
to define the desired value.